- Maximum centrifugation speeds of 700,000 x g (90,000 rpm in Centrifuge CP90NX with Rotor P90AT)
- Maximum capacity of 1,380 mL (6 x 230 mL bottles in Rotor P21A2)
- RLM System and Rotor ID detection for an extended rotor lifetime
- Quiet operation (<51 dB[A]) to improve your work environment
- Easy balancing of samples (eye level within 5 mm) due to non-contact imbalance sensor1)
- Large 6.5-inch touch display with intuitive operation (11 languages)
- Remote operation and monitoring with mobile phone and optional log management software
- Low table height with smooth sliding door for easy loading and unloading of centrifuge and rotor
- Front-mounted LED status bar shows operating status at a glance and from the distance
- Biosafety option available (micro filter modification at factory or on-site)
ZA | ZAR
ZA | ZAR
-
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifugation Consumables
- Accessories
- Tubes
- Plates
- Device Management Software
- Sample and Information Management
Centrifuge CP90NX
Product Information
- refrigerated
- touch interface, 220 V/50/60 Hz (no plug), 20 A
You will find additional download material at the bottom of this page
Technical Data
Features
Technical Data
Specifications | CP90NX |
---|
Max. RCF | 700000 × g |
Heat output | 1 kW |
Speed | 1000 – 90000 rpm (100 rpm steps) |
Max. capacity | 6 x 230 mL (P21A2) |
Number of programs | 1000 |
Timer | from 1 min to 999 h 59 min (with 1 min increments) with HOLD function |
Noise level | 51 dB(A) |
Interfaces | USB : 1xHost, 1xDevise / 1xLAN |
Power supply | 220 V, 50/60 Hz |
Max. power consumption | 1000 W |
Dimensions (W × D × H) | 790 × 690 × 880 mm / 31.1 × 27.1 × 34.6 in |
Footprint (dimensions w/o front panel, WxD) | 790 x 890 mm |
Product weight | 390 kg / 860 lb |
Height (with open lid) | 880 cm / 34.6 in |
Cooling | refrigerated |
Cooling system | Thermo-module cooling system (CFC/HCFC/HFC-free) |
Temperature accuracy | ±0.5 °C |
Operating temperature |
Ambient temperature for operation: 2 °C to 40 °C Ambient temperature for performance guarantee: 10 °C to 30 °C |
Acceleration/Deceleration mode |
Acceleration: 10 modes Deceleration: 11 modes (10 and coasting) |
Keypad | 6.5'' touch-sensitive color LCD panel |
Power requirement |
Single phase: AC200/208/220 V±10%, Max. 20 A (normally 8 A) Single phase: AC230/240 V ±10%, Max. 16 A (normally 7 A) |
Vacuum system | Oil rotary vacuum pump and oil diffusion pump |
Rotor life management |
Automatic Rotor Life Management for rotors with RLM adapter Registered by serial number to the system for rotors with optical overspeed disk |
Brake system | Regenerative braking (with energy recovery) |