- Swing-bucket rotors and adapters accommodate tubes and bottles from 0.2 mL to 250 mL
- Plate rotor for centrifugation of all types of MTP, PCR, cell culture, or Deepwell Plates
- Fixed-angle rotors for high-speed applications in tubes from 0.2 mL to 85 mL
- High centrifugation speed of up to 20,913 × g (14,000 rpm)
- Centrifuge lid with soft-touch lid closure
- Low access height of 29 cm for easy loading and unloading of samples
- Quiet operation to improve your work environment
- Compact footprint saves valuable bench space
- Automatic rotor recognition and imbalance detection for maximum operational safety
-
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifugation Consumables
- Accessories
- Tubes
- Plates
- Device Management Software
- Sample and Information Management
- IVD Products
Centrifuge 5804 R (EU-IVD)
The Centrifuge 5804/ 5804 R is a non-automatic centrifuge for the separation of liquid substance mixtures from the human body and is specifically intended to be used as an accessory together with an in vitro diagnostic device and to enable its use according to its intended purpose. This product complies with the requirements of the EU In Vitro Diagnostics Regulation (IVDR) 2017/746. Eppendorf centrifuges are exclusively intended for indoor use by trained specialists.
-
IVD
Product Information
- keypad, refrigerated, without rotor
- 230 V/50 – 60 Hz (GB)
You will find additional download material at the bottom of this page
Technical Data
Features
Technical Data
Specifications | 5804 R |
---|
Max. RCF | 20913 × g |
Max. RCF with fixed-angle rotor | 20913 × g |
Max. RCF with swing-bucket rotor | 4500 × g |
Max. RCF with plate rotor | 2250 × g |
Speed | 200 – 14,000 rpm (10 rpm steps) |
Product type | Centrifuges |
Rotors available | 12 |
Max. capacity | 4 × 250 mL/ 2 × 5 MTP |
Acceleration/braking ramps | 10/10 |
Number of programs | 35 user-defined programs |
Timer | 1 min to 99 min, with continuous run function, short-spin |
Noise level | < 58 dB(A) |
Power supply | 230 V, 50 – 60 Hz |
Max. power consumption | 1650 W |
Dimensions (W × D × H) | 63.4 × 55.0 × 34.2 cm / 25.0 × 21.7 × 13.5 in |
Footprint (dimensions w/o front panel, WxD) | 64 × 50 cm |
Product weight | 80 kg / 176 lb |
Height (with open lid) | 74 cm / 29 in |
Cooling | refrigerated |
Temperature range | -9 °C to 40 °C |
Max. capacity |
|
Conical tubes | 40 × 15 mL (with Rotor F-35-48-17) / 16 × 50 mL |
Plates | 10 × MTP/ 2 × DWP |
Blood collection tubes | 56 × 13 mm/ 52 × 16 mm |
Noise level |
|
Rotor FA-45-6-30 (6×50 mL) | <54 dB(A) |
Rotor S-4-72 (4×250 mL) | <58 dB(A) |
Features
- Temperature range from -9 °C to 40 °C
- FastTemp function for fast pre-cooling
- Continuous cooling maintains a constant temperature after the run has been completed – your samples stay cool
- ECO shut-off engages after 8 hours of non-use to reduce energy consumption and to extend compressor life
- Dynamic compressor control (DCC) technology for optimized cooling performance