CN | CNY
CN | CNY
软件下载
软件和固件更新
此网页免费提供软件/固件修订版,所有用户便可以从最新的性能增强中受益。升级过程十分简便,只需几分钟即可执行。
显示更少
注意: 客户如需在受控环境中操作配备软件或固件的 Eppendorf 产品,请在下载和安装任何软件或固件前咨询公司,确认相关质量保证、资格认证。
显示更少
Pipette Updates
Eppendorf Pipette Software Update Tool
Eppendorf Pipette Software Update Tool
NOTE: The update tool will connect to the Eppendorf servers to download the latest software update for your electronic Eppendorf pipette. Instructions how to install the update are included in the .zip file.
WARNING: With a software update, the pipette is reset to factory settings and all settings and saved programs or favorites (if any) are deleted.
Download ep_update_tool_version_00.02.00.zip
Latest update/Version
11-Nov-2024
Rev. 06.03.00 for Multipette® / Repeater® E3 or E3x
31-Jul-2024
Rev. 05.07.00 for Eppendorf Xplorer® , Xplorer plus or Xplorer plus Move It®
Description of Changes
Revision 06.03.00 for Multipette® / Repeater® E3 or E3x
Revision 05.07.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
Previous Versions
24-Jan-2024
Revision 05.06.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
06-Mar-2023
Rev. 05.05.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
04-Nov-2022
Revision 06.02.00 for Multipette® / Repeater® E3 or E3x
23-May-2022
Rev. 05.02.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
07-Mar-2022
Rev. 05.01.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
Rev. 06.01.00 for Multipette® / Repeater® E3 or E3x
16-Jul-2021
Rev. 04.02.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
Rev. 05.01.00 Multipette® / Repeater® E3 or E3x
WARNING: With a software update, the pipette is reset to factory settings and all settings and saved programs or favorites (if any) are deleted.
Download ep_update_tool_version_00.02.00.zip
Latest update/Version
11-Nov-2024
Rev. 06.03.00 for Multipette® / Repeater® E3 or E3x
31-Jul-2024
Rev. 05.07.00 for Eppendorf Xplorer® , Xplorer plus or Xplorer plus Move It®
Description of Changes
Revision 06.03.00 for Multipette® / Repeater® E3 or E3x
- Updated user interface design and graphics for error messages
Revision 05.07.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
- Added compatibility with Pipette Manager software 1.2.3
Previous Versions
24-Jan-2024
Revision 05.06.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
- Several improvements and bugfixes when using the pipette with Eppendorf Pipette Manager
06-Mar-2023
Rev. 05.05.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
- Added compatibility with Pipette Manager software 1.1.3
04-Nov-2022
Revision 06.02.00 for Multipette® / Repeater® E3 or E3x
- Several improvements and bugfixes when using the pipette with Eppendorf Pipette Manager
23-May-2022
Rev. 05.02.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
- Updated device drivers for new memory module in pipettes produced from 2022 (no changes for pipettes purchased before 2022)
07-Mar-2022
Rev. 05.01.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
- Added support for new circuit board in pipettes produced from 2022 (no changes for pipettes purchased before 2022)
Rev. 06.01.00 for Multipette® / Repeater® E3 or E3x
- Optimized overvoltage protection
- Improved wake-up/sleep function
- Improved read & write function of user settings
16-Jul-2021
Rev. 04.02.00 for Eppendorf Xplorer® , Xplorer plus and Xplorer plus Move It®
- Improved battery capacity measurement
- Improved read & write function of user settings
- Support for Eppendorf Xplorer® connect WiFi module for connection to Eppendorf Pipette Manager
- Integration of an automatic blow out in reverse pipetting mode
Rev. 05.01.00 Multipette® / Repeater® E3 or E3x
- Improved battery capacity measurement
- Improved read & write function of user settings
显示更少
Pipette Manager Updates
NOTE: Empty USB flash drive with at least 512 MB storage space in FAT32 format needed to perform an update. Instructions how to install the update are included in the .zip file. Important: Please insert the USB drive only after booting up the Pipette Manager.
Download Pipettemanager_software_update.zip
Latest update/Version
31-Jul-2024
Rev. 1.2.3
Description of Changes
Previous Versions
31-Mar-2023
Rev. 1.1.3
Description of Changes
15-Nov-2021
Rev. 1.0.10
Description of Changes
09-Mar-2021
Rev. 1.0.06
Description of Changes
Download Pipettemanager_software_update.zip
Latest update/Version
31-Jul-2024
Rev. 1.2.3
Description of Changes
- Added additional features to the "Pipetting Records" feature:
-
- Records can now be exported in .CSV and .PDF formats (previously only PDF)
- Users can now add "Quick Notes" to recorded activities which are included in the Record
- The Record header can now be customized with individual logos (previously only Eppendorf logo)
Previous Versions
31-Mar-2023
Rev. 1.1.3
Description of Changes
- Added new feature Pipetting Records, allowing documentation of pipetting activities and export via PDF file
- Improved WiFi communication with connected pipettes and tablets
- Minor improvements
15-Nov-2021
Rev. 1.0.10
Description of Changes
- Added support for Move It® Adjustable Tip Spacing Pipettes
- Prevention of firmware downgrades for pipettes with a newer firmware version during the firmware update via the VisioNize® pipette manager
- Minor bugs fixed
09-Mar-2021
Rev. 1.0.06
Description of Changes
- Initial product version
显示更少
VisioNize更新
VisioNize Box模块更新
显示更少
超低温冰箱更新
RackScan Analyze
注意:RackScan Analyzer软件用于读取耗材上的二维数据矩阵代码,传输里面包含的信息,以便在软件应用程序中进一步使用。
为了能与RackScan b和RackScan s一起使用,RackScan Analyzer软件应运而生。
变更说明
zip文件包括以下文件:
Date/File/Version
20-Dec-2019
Version: 3.15 (build 3129)
为了能与RackScan b和RackScan s一起使用,RackScan Analyzer软件应运而生。
变更说明
zip文件包括以下文件:
- Eppendorf RackScan Analyzer安装程序
- 软件手册,包括安装指南
Date/File/Version
20-Dec-2019
Version: 3.15 (build 3129)
显示更少
温度控制与混匀仪更新
ThermoMixer® C、ThermoMixer® F和ThermoStat® C更新
变更说明
软件版本3.5.0引入了一个新的应用程序功能,用于解冻细胞,该功能专为Eppendorf ThermoMixer® C与新的Eppendorf SmartBlock™解冻模块结合使用。[1] 此外,对于Eppendorf ThermoMixer® C、ThermoMixer® F和ThermoStat® C还有一些微小新增、更新和修复,例如
• 通过特殊程序中的LED和简单旋律发送用户通知(例如 “解冻细胞”)
• 保存在程序键上的混匀程序可以重置为默认值(仅限ThermoMixer C)
• 可与VisioNize模块进行扩展通信
• 以前对话框只有英文版,现在则可进行翻译
• 调整显示文本的长度,从而更好地适应GUI
• 改进了内存处理(参见下面的警告)
• 修复了多条目菜单的滚动方式
Date/File/Version
26-Nov-20
软件版本3.5.0引入了一个新的应用程序功能,用于解冻细胞,该功能专为Eppendorf ThermoMixer® C与新的Eppendorf SmartBlock™解冻模块结合使用。[1] 此外,对于Eppendorf ThermoMixer® C、ThermoMixer® F和ThermoStat® C还有一些微小新增、更新和修复,例如
• 通过特殊程序中的LED和简单旋律发送用户通知(例如 “解冻细胞”)
• 保存在程序键上的混匀程序可以重置为默认值(仅限ThermoMixer C)
• 可与VisioNize模块进行扩展通信
• 以前对话框只有英文版,现在则可进行翻译
• 调整显示文本的长度,从而更好地适应GUI
• 改进了内存处理(参见下面的警告)
• 修复了多条目菜单的滚动方式
Date/File/Version
26-Nov-20
显示更少
生物工艺更新
Analog 输入/输出模块更新
变更说明
↲Analog I/O软件修订版B.00版,拥有从单个安装版本识别和控制多达8个Analog I/O模块的能力,解决了通信丢失问题。
日期/文件/版本
2019年1月30日
Update_M1372_B.00.zip
Version Analog B.00
↲Analog I/O软件修订版B.00版,拥有从单个安装版本识别和控制多达8个Analog I/O模块的能力,解决了通信丢失问题。
日期/文件/版本
2019年1月30日
Update_M1372_B.00.zip
Version Analog B.00
显示更少
BioCommand® Batch Control更新
警告:请勿尝试在BioCommand® Batch Control Plus安装中安装此更新。数据库文件不兼容,可能会导致数据丢失。有关BioCommand® Batch Control Plus更新,请联系您当地的销售/售后工程师。
变更说明
修订版6.03包括以下功能增强:
日期/文件/版本
2023年6月30日
v6.03
此处下载
变更说明
修订版6.03包括以下功能增强:
- SQL Server已从SQL Server 2008 Express更新为SQL Server 2017 Express
- SQL登录密码长度和复杂性增加
- 发布者证书已添加到BioCommand和NBS OPC服务器向导应用程序
日期/文件/版本
2023年6月30日
v6.03
此处下载
显示更少
BioCommand® Batch Control Plus更新
对于BioCommand Batch Control Plus,5.01版需要特定的软件更新程序。请联系您当地的Eppendorf售后工程师以获取更多信息。
显示更少
BioCommand®跟踪和趋势分析更新
警告:请勿尝试在BioCommand® Batch Control Plus安装中安装此更新。数据库文件不兼容,可能会导致数据丢失。有关BioCommand® Batch Control Plus更新,请联系您当地的销售/售后工程师。
变更说明
修订版6.03包括以下功能增强:
日期/文件/版本
2023年6月30日
v6.03
此处下载
变更说明
修订版6.03包括以下功能增强:
- SQL Server已从SQL Server 2008 Express更新为SQL Server 2017 Express
- SQL登录密码长度和复杂性增加
- 发布者证书已添加到BioCommand和NBS OPC服务器向导应用程序
日期/文件/版本
2023年6月30日
v6.03
此处下载
显示更少
BioFlo® 120更新
软件修订版02.08包含以下解决方案/新增功能,可提高您的生物工艺控制系统性能:
日期/文件/版本
2021年3月25日
1390_1203_02.08.zip
版本 02.08
- 新增具有不同调节比支持的1SLPM和5SLPM TMFC
日期/文件/版本
2021年3月25日
1390_1203_02.08.zip
版本 02.08
显示更少
BioFlo® 320更新
软件修订版04.07包含以下解决方案/新增功能,可提高您的生物工艺控制系统的性能:
日期/文件/版本
2023年11月10日
M1379-1203_Rev_04_07_0011.zip
版本04.07
此处下载
- 增加2点校准用于变速泵
- 已更新键盘以添加其他字符。
- 在气体混合和手动模式下使用低流量多1SLPM TMFC抽屉时,增加了组合总流量/最大流量限制。
- 4气体混合物、3气体混合物、4气体手动、3气体手动–3SLPM
- O2气体混合物,2气体手动–2SLPM
- N2 气体混合物,2 气体手动–1 SLPM(无更改)
- 各种小问题
日期/文件/版本
2023年11月10日
M1379-1203_Rev_04_07_0011.zip
版本04.07
此处下载
显示更少
BioFlo®/CelliGen 510更新
请联系您当地的 Eppendorf 售后工程师以获取更多信息
显示更少
BioFlo® 610更新
请联系您当地的 Eppendorf 售后工程师以获取更多信息
显示更少
BioFlo® 720更新
Description of Changes:Software revision 02.01 incorporates the following solutions/additions to improve the performance of your bioprocess controller:
14-June-2024
BioFlo 720 Updates.zip
- Hamilton ARC sensor compatibility
- All stop button
- Scale Up Assist (Custom vessel & BioFlo 320 water-jacketed vessels have been added)
14-June-2024
BioFlo 720 Updates.zip
显示更少
RS-232 OPC服务器更新
显示更少
SciVario®更新
Please contact your local Eppendorf service representative for assistance
Latest version 1.4.0.r113
This software version is compatible to DASware control 6.3 or higher
Latest version 1.4.0.r113
This software version is compatible to DASware control 6.3 or higher
显示更少
显示更少