RS | RSD
RS | RSD
-
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifugation Consumables
- Accessories
- Tubes
- Plates
- Device Management Software
- Sample and Information Management
- IVD Products
BioFlo® 510
Cell Culture Impellers
Videos not loading, because cookies have been rejected. Change your
BioCommand Setup
Videos not loading, because cookies have been rejected. Change your
Product Information
SIP benchtop reactors designed to meet the needs of R&D through production.You will find additional download material at the bottom of this page
Services (6)
6 Services
|
|
|
|
|
|
Show more Products
Added to Your Cart
Product Information
Applications
Features
Product Information
The BioFlo 510 is a compact sterilizable-in-place fermentation system ideal for pilot to small scale production processes. The modular design features a wide variety of standard options allowing this system to be flexible enough to meet most process requirements.
Gas flow
• Various combinations of one, two, three or four TMFCs:
0.06 – 3 SLPM
0.3 – 15 SLPM
0.6 – 32 SLPM
1 – 64 SLPM
• Overlay (valve only)
Exhaust line
• Exhaust condenser
• Manual or automatic pressure control
Impellers
• Rushton-type – Used commonly for robust cell lines such as bacteria, yeasts, and algae, where maximum OTR is desired. Provided as standard on BioFlo 510 fermentors
• Pitched-blade – Commonly used with mammalian, insect or other shear sensitive cell lines for batch, fed-batch or continuous cultures. Produces axial and radial mixing.
• Marine – Commonly used with mammalian, insect, or other shear sensitive cell lines for batch, fed-batch or continuous cultures. Produces axial mixing
Sensors
• Single or redundant pH/DO
• Redox
• Foam/level
Addition and sampling
• Resterilizable sampling valve
• Resterilizable addition valves (4 max)
• Resterilizable addition/harvest valve with dip tube (2 max)
• 1.5 in sanitary fitting 7-port septum
• Addition vessels (glass/stainless steel)
• Sterile sampling assembly
Validation
• Basic Package
• Basic Plus Package
• Enhanced Package
Utility regulator & pre-filter kits
• Process air pre-filter/regulator kit
• Instrument air pre-filter/regulator kit
• Water pre-filter/regulator kit
• Process steam regulator kit
• Utility steam pre-filter/regulator kit
• Utility connection kit
Additional options
• Sprayballs for clean-in-place of vessel
• External variable-speed pumps
• External scales
• Spare parts kits
• Preventive maintenance kits
• Mobile table
• System passivation
• Glycol/chiller heat exchanger
Gas flow
• Various combinations of one, two, three or four TMFCs:
0.06 – 3 SLPM
0.3 – 15 SLPM
0.6 – 32 SLPM
1 – 64 SLPM
• Overlay (valve only)
Exhaust line
• Exhaust condenser
• Manual or automatic pressure control
Impellers
• Rushton-type – Used commonly for robust cell lines such as bacteria, yeasts, and algae, where maximum OTR is desired. Provided as standard on BioFlo 510 fermentors
• Pitched-blade – Commonly used with mammalian, insect or other shear sensitive cell lines for batch, fed-batch or continuous cultures. Produces axial and radial mixing.
• Marine – Commonly used with mammalian, insect, or other shear sensitive cell lines for batch, fed-batch or continuous cultures. Produces axial mixing
Sensors
• Single or redundant pH/DO
• Redox
• Foam/level
Addition and sampling
• Resterilizable sampling valve
• Resterilizable addition valves (4 max)
• Resterilizable addition/harvest valve with dip tube (2 max)
• 1.5 in sanitary fitting 7-port septum
• Addition vessels (glass/stainless steel)
• Sterile sampling assembly
Validation
• Basic Package
• Basic Plus Package
• Enhanced Package
Utility regulator & pre-filter kits
• Process air pre-filter/regulator kit
• Instrument air pre-filter/regulator kit
• Water pre-filter/regulator kit
• Process steam regulator kit
• Utility steam pre-filter/regulator kit
• Utility connection kit
Additional options
• Sprayballs for clean-in-place of vessel
• External variable-speed pumps
• External scales
• Spare parts kits
• Preventive maintenance kits
• Mobile table
• System passivation
• Glycol/chiller heat exchanger
Applications
- Laboratory- and pilot-scale fermentation of aerobic and anaerobic bacteria, yeasts, and fungi
- Laboratory- and pilot-scale cell culture of mammalian, insect, and human cell lines
- Special applications such as stem cell culture, vaccine, monoclonal antibody or biofuel/biopolymer production
- Suitable for batch, fed-batch, and continuous/perfusion processes
Features
- RPC (Reactor Process Control) software
- 32.0 L working volume stainless-steel electropolished vessels with 2:1 aspect ratios
- Integrated load cell
- 3-fixed speed peristaltic pumps for the additions, harvest and pH control
- Benchtop or Mobile option
- Includes Rushton-type impellers with pitched-blade and marine blade option
- Industrial touchscreen interface