Pipette Service and Calibration (ISO 8655 and ISO 17025)
Please contact us today:
Read more
Read less
Do something good for your pipettes!
The quality of your work results is significantly influenced by the precision and accuracy of your pipettes and dispensers. Pipettes are precision instruments whose normal wear leads to inaccuracies over time. With regular maintenance and calibration to maintain the precision and accuracy of your pipettes from Eppendorf and other manufacturers, the quality of your results is ensured in the long term.
The ISO 8655-6:2022 is an international standard for calibration and testing procedures of piston-operated volumetric apparatus like pipettes, burettes, dilutors, and dispensers, which must be performed at least once a year. It defines the respective criteria and which maximum permissible error limits should be used at each volume tested. ISO 8655 criteria include the tip usage for pipettes (pipette and tip as one system), number of measurements and volumes, controls for room environment, and the permissible quality of the test chain.
Our calibration service ensures that our stringent and validated procedures for pipettes and dispensers from Eppendorf and other brands (e.g. Gilson, Mettler Toledo, ThermoFisher, Sartorius, etc.) comply with the highest possible standards and are also ISO 17025 accredited (DAkkS, DKD, ILAC, ENAC, COFRAC and others). ISO/IEC 17025 criteria include a traceability chain for measurement equipment, measurement uncertainty values, and approved quality standards for testing and calibration – such as precisely achieving desired environmental conditions. The service processes have been audited extensively by an independent regulatory authority. The laboratory equipment has been certified by another accredited calibration laboratory.
Read more
Read less
Pipette Calibration Service
Service | Calibration measurements »As Is« | Calibration measurements »As Left« | Decontamination from outside*2 | Checking, cleaning, lubricating*4 before calibration | Single channel pipette/dispenser | 8-channel pipette | 12-channel pipette | 16-channel pipette | 24-channel pipette |
ISO 8655 without Preventive Maintenance | 10 per test volume*1 | included | |||||||
ISO 8655 including Preventive Maintenance | 10 per test volume*1 | included | included | ||||||
3×4 without Preventive Maintenance | 4 per test volume*1 | included | |||||||
3×4 including Preventive Maintenance | 4 per test volume*1 | included |
Read more
Read less
Calibration Service Packages – Ordering information
Service | Calibration measurements »As Is« | Calibration measurements »As Left« | Outside decontamination*2 ; checking, cleaning, lubrication*4 | ISO 17025 Accredition calibration certificate | Single channel pipette/dispenser | 8-channel pipette | 12-channel pipette | 16-channel pipette | 24-channel pipette |
ISO 8655 Verified | 4 per test volume*1 | 10 per test volume*1 | included | ||||||
ISO 17025 including Preventive Maintenance | 10 per test volume*1 | included | included | ||||||
ISO 17025 Advanced | 4 per test volume*1 | 10 per test volume*1 | included | included*3 | |||||
ISO 17025 Professional | 10 per test volume*1 | 10 per test volume*1 | included | included |
Read more
Read less
Additional Services
Ordering Information | |
ISO 17025 Calibration Services | |
Advanced Documentation, Excel file for calibration information on all pipettes/dispenser per order | |
Charges | |
On-site calibration services in your own laboratory | inquire |
Labor Charge, 15 min. of repair services, time unit of one technician |
Read more
Read less
*1 10%, 50% and 100% of nominal volumes for variable volume instruments.
*2 Pipettes and dispensers and package equipment need to be decontimated before sending in.
*3 ISO 17025 accreditation calibration certificate is included in the second calibration after the maintenance.
*4 Internal parts
Read more
Read less
Service offers may differ by country.