MENU
PL | PLN
PL | PLN
Nie znaleziono wyników
Sugestie wyszukiwania
Eppendorf twin.tec® real-time PCR Plates - płytka do qPCR
PCR plates dedicated to qPCR
![PCR plates dedicated to qPCR Using special real-time PCR plates can increase your results](/product-media/img/global/0030132505_MW__004834/Eppendorf_Sample-Preparation_twintec-real-time-PCR-plate-96-group_stacked_product.jpg?imwidth=920)
Eppendorf twin.tec® real-time PCR plates (96 wells, stackable)
Underside of Eppendorf twin.tec® real-time PCR plate
![Underside of Eppendorf twin.tec® real-time PCR plate Underside of an Eppendorf twin.tec_REG_ real-time PCR plate](/product-media/img/global/54759/PCR_twintec-realtime-PCR_product.jpg?imwidth=920)
Underside of a 96-well qPCR plate
Open Forensic DNA Grade qPCR plate
![Open Forensic DNA Grade qPCR plate Forensic DNA grade qPCR plates are individually wrapped](/product-media/img/global/214483/Eppendorf_Sample-Preparation_Forensic-DNA-Grade-twintec-real-time-PCR-Plate-96_packaging-opened_product.jpg?imwidth=920)
Zapobiegaj zanieczyszczeniom w czasie przechowywania, stosując oddzielnie pakowane płytki do qPCR forensic DNA grade
Forensic DNA Grade qPCR plate wrapped
![Forensic DNA Grade qPCR plate wrapped Individually wrapped forensic DNA grade qPCR plates](/product-media/img/global/214482/Eppendorf_Sample-Preparation_Forensic-DNA-Grade-twintec-real-time-PCR-Plate-96_packaging-opened_product.jpg?imwidth=920)
Płytki do qPCR Forensic DNA grade są pakowane oddzielnie, aby zapobiegać zanieczyszczeniom
Eppendorf Consumables - behind the scenes!
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/n1GmLRpHkNE/hqdefault.jpg)
Informacje o produkcie
Białe dołki płytek Eppendorf twin.tec® real-time PCR plates skutecznej odbijają światło fluorescencyjne podczas real-time PCR (qPCR) i innych eksperymentów fluorescencyjnych. Intensywniejsze światło fluorescencyjne emitowane z tych specjalnych płytek do qPCR zwiększa czułość eksperymentów, jednocześnie poprawiając odtwarzalność i spójność wyników.Dalsze materiały do pobrania znajdują sięna dole strony
Produkty (8)
Akcesoria (1)
8 Produkty
|
|
|
|
|
|
|
|
Pokaż więcej produktów
Dodano do koszyka
Informacje o produkcie
Zastosowania
Cechy
Czynnikiem ograniczającym metody real-time PCR (qPCR) stosowane na małych objętościach jest często niewielkie natężenie fluorescencji. Eppendorf twin.tec real-time PCR plates są idealnym rozwiązaniem do qPCR, ponieważ oferują te same zalety co zwykłe płytki twin.tec, a jednocześnie mają białe dołki. Zapewniają one lepsze odbijanie światła fluorescencyjnego niż w przypadku dołków przezroczystych lub matowych, dzięki czemu możesz za pomocą tego samego urządzenia wykrywać niższe poziomy fluorescencji – wystarczy tylko użyć odpowiednich materiałów zużywalnych. Oprócz tego białe dołki w płytkach do qPCR znacząco zmniejszają fluorescencję tła i zwiększają zgodność rezultatów pomiędzy powtórzeniami, co zapewnia wysoką odtwarzalność wyników.
Dołki są wykonane z polipropylenu – co gwarantuje szybki transfer ciepła i skraca czas eksperymentu – natomiast ramka jest zrobiona ze sztywnego poliwęglanu, który ułatwia obsługę – zarówno podczas pracy manualnej jak i automatycznej.
Dołki są wykonane z polipropylenu – co gwarantuje szybki transfer ciepła i skraca czas eksperymentu – natomiast ramka jest zrobiona ze sztywnego poliwęglanu, który ułatwia obsługę – zarówno podczas pracy manualnej jak i automatycznej.
![Comparison of Reflection between white and frosted wells 1 Fluorescence intensity graph in Eppendorf twin.tec_REG_ real-time PCR plates](/product-media/img/global/Intensity_blue_cyan_neu/Eppendorf_Sample-Preparation_Comparison-Reflection-white-frosted-wells_1_diagram.jpg?imwidth=920)
![Comparison of Reflection between white and frosted wells 1 Fluorescence intensity graph in Eppendorf twin.tec_REG_ real-time PCR plates](/product-media/img/global/Intensity_blue_cyan_neu/Eppendorf_Sample-Preparation_Comparison-Reflection-white-frosted-wells_1_diagram.jpg?imwidth=540)
Wysoka intensywność fluorescencji ma kluczowe znaczenie dla czułości qPCR. Ten wykres pokazuje nawet 10-krotnie wyższą intensywność fluorescencji w płytkach twin.tec® do real-time PCR w porównaniu do matowych dołków.
![Comparison of Reflection between white and frosted wells 1 Fluorescence intensity graph in Eppendorf twin.tec_REG_ real-time PCR plates](/product-media/img/global/Intensity_blue_cyan_neu/Eppendorf_Sample-Preparation_Comparison-Reflection-white-frosted-wells_1_diagram.jpg?imwidth=920)
![Comparison of Reflection between white and frosted wells 1 Fluorescence intensity graph in Eppendorf twin.tec_REG_ real-time PCR plates](/product-media/img/global/Intensity_blue_cyan_neu/Eppendorf_Sample-Preparation_Comparison-Reflection-white-frosted-wells_1_diagram.jpg?imwidth=540)
![Comparison of different plate wells Increased fluorescent signal reduces Ct values in qPCR.](/product-media/img/global/Grafik_Ct_shift_GB_v1_neu/Eppendorf_Sample-Preparation_Comparison-different-plate-wells_diagram.jpg?imwidth=920)
![Comparison of different plate wells Increased fluorescent signal reduces Ct values in qPCR.](/product-media/img/global/Grafik_Ct_shift_GB_v1_neu/Eppendorf_Sample-Preparation_Comparison-different-plate-wells_diagram.jpg?imwidth=540)
Eppendorf twin.tec® real-time PCR plates redukują wartości Ct skuteczniej od innych testowanych płytek. Wartości Ct były średnio o 0,8 cykla niższe (w porównaniu do przezroczystych dołków), co wskazuje na wyższą intensywność.
![Comparison of different plate wells Increased fluorescent signal reduces Ct values in qPCR.](/product-media/img/global/Grafik_Ct_shift_GB_v1_neu/Eppendorf_Sample-Preparation_Comparison-different-plate-wells_diagram.jpg?imwidth=920)
![Comparison of different plate wells Increased fluorescent signal reduces Ct values in qPCR.](/product-media/img/global/Grafik_Ct_shift_GB_v1_neu/Eppendorf_Sample-Preparation_Comparison-different-plate-wells_diagram.jpg?imwidth=540)
![Comparison of different plate wells 1 Results are more homogeneous when using white wells.](/product-media/img/global/Grafik_SD_reduction_GB_v2_neu/Eppendorf_Sample-Preparation_Comparison-different-plate-wells_1_diagram.jpg?imwidth=920)
![Comparison of different plate wells 1 Results are more homogeneous when using white wells.](/product-media/img/global/Grafik_SD_reduction_GB_v2_neu/Eppendorf_Sample-Preparation_Comparison-different-plate-wells_1_diagram.jpg?imwidth=540)
Białe dołki zwiększają jednolitość wyników w całym bloku. Na tym wykresie można zaobserwować zmniejszone odchylenie standardowe w ramach bloku, w porównaniu do innych płytek.
![Comparison of different plate wells 1 Results are more homogeneous when using white wells.](/product-media/img/global/Grafik_SD_reduction_GB_v2_neu/Eppendorf_Sample-Preparation_Comparison-different-plate-wells_1_diagram.jpg?imwidth=920)
![Comparison of different plate wells 1 Results are more homogeneous when using white wells.](/product-media/img/global/Grafik_SD_reduction_GB_v2_neu/Eppendorf_Sample-Preparation_Comparison-different-plate-wells_1_diagram.jpg?imwidth=540)
Przeczytaj więcej
Przeczytaj mniej
- Real-time PCR
- Analiza krzywej topnienia
- Białe dołki zapewniają lepsze odbijanie
- Wysoka odporność mechaniczna
- Skuteczne uszczelnianie dzięki podwyższonym brzegom dołków
- Ramki o obrzeżach typu skirted i semi-skirted
- Niezwykle cienka ścianka zapewnia optymalne przewodzenie ciepła
- Autoklawowalne (121 °C, 20 min)
- Dostępne z kodem kreskowym (na zamówienie)
- Dostępne w stopniach czystości PCR clean i Eppendorf Forensic DNA Grade certyfikowanych oddzielnie dla każdej partii