Pipety Move It® z regulacją odległości pomiędzy końcówkami - Pipeta regulowana
Move It® adjustable tip spacing multi-channel pipettes from Eppendorf
![Move It® adjustable tip spacing multi-channel pipettes from Eppendorf Move It_REG_ adjustable tip spacing multi-channel pipettes from Eppendorf](/product-media/img/global/813580/Eppendorf_Liquid-Handling_Xplorer-plus-8-channels-1200uL-Research-plus-4-channels-300uL_product.jpg?imwidth=920)
Move It® adjustable tip spacing multi-channel pipettes are the ideal dispensing tool when switching vessel formats
![Move It® adjustable tip spacing multi-channel pipettes are the ideal dispensing tool when switching vessel formats Move It_REG_ adjustable tip spacing multi-channel pipettes are the ideal dispensing tool when switching vessel formats](/product-media/img/global/814277/Eppendorf_Liquid-Handling_Research-plus-Multichannel-Pipette-8-channels_key-visual.jpg?imwidth=920)
Quickly move samples across different vessel formats – with ease!
![Quickly move samples across different vessel formats – with ease! Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=920)
Increase precision, accuracy, and durability with our adjustable tip spacing multichannel pipette
![Increase precision, accuracy, and durability with our adjustable tip spacing multichannel pipette Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=920)
1) Warianty Research plus w całości, a w przypadku Xplorer plus tylko dolną część.
Eppendorf Research® plus Move It® 8-channel pipette, 5 – 100 µL, light yellow
![Eppendorf Research® plus Move It® 8-channel pipette, 5 – 100 µL, light yellow Mechanical Eppendorf Research_REG_ plus Move It_REG_ adjustable tip spacing pipette with 8 channels](/product-media/img/global/780303/Eppendorf_Liquid-Handling_Research-plus-8-channels-100uL_product.jpg?imwidth=920)
Eppendorf Xplorer® plus Move It® 6-channel pipette, 15 – 300 µL, orange
![Eppendorf Xplorer® plus Move It® 6-channel pipette, 15 – 300 µL, orange Eppendorf Xplorer_REG_ plus Move It_REG_ electronic pipette with 6 adjustable channels](/product-media/img/global/783996/Eppendorf_Liquid-Handling_Xplorer-plus-6-channels-300uL_product.jpg?imwidth=920)
Move It® adjustable tip spacing multi-channel pipettes work without any tubing connections between cone and piston-cylinder system
![Move It® adjustable tip spacing multi-channel pipettes work without any tubing connections between cone and piston-cylinder system Move It_REG_ Adjustable Tip Spacing Pipettes: Transparent Lower Part in Action (GIF, Frontal View)](/product-media/doc/global/1119083/Liquid-Handling_Move-It-Animation1_GIF.gif?imwidth=920)
Easily and quickly adjust tip spacing with a manual adjustment knob
![Easily and quickly adjust tip spacing with a manual adjustment knob Move It_REG_ Adjustable Tip Spacing Pipettes: Transparent Lower Part in Action (GIF, Side View)](/product-media/doc/global/1119088/Liquid-Handling_Move-It-Animation2_GIF.gif?imwidth=920)
Female Scientist using Eppendorf Research® plus Move It® Pipette for Easy Liquid Transfer Between Vessel Formats
![Female Scientist using Eppendorf Research® plus Move It® Pipette for Easy Liquid Transfer Between Vessel Formats Female Scientist using Eppendorf Research_REG_ plus Move It_REG_ Pipette for Easy Liquid Transfer Between Vessel Formats](/product-media/img/global/1735384/Eppendorf_Liquid-Handling_Research-plus-Move-It_people-lab-scene.jpg?imwidth=920)
Accelerate and simplify synchronous pipetting of a series of samples and experience a new joy in the lab!
![Accelerate and simplify synchronous pipetting of a series of samples and experience a new joy in the lab! Scientist using a Move It_REG_ adjustable tip spacing pipette to transfer liquid from a series of tubes to a plate](/product-media/img/global/763053/Eppendorf_Liquid-Handling_Move-It-handling-scene-5_people-lab-scene.jpg?imwidth=920)
Choose Move It® pipettes with a minimum cone spacing of 4.5 mm when working with 384-well plates
![Choose Move It® pipettes with a minimum cone spacing of 4.5 mm when working with 384-well plates Scientist using a Move It_REG_ adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=920)
The software of your Eppendorf Xplorer® plus pipette can easily be updated using the Pipette Software Update Tool
![The software of your Eppendorf Xplorer® plus pipette can easily be updated using the Pipette Software Update Tool The software of your Eppendorf Xplorer_REG_ plus pipette can easily be updated using the Pipette Software Update Tool](/product-media/img/global/1075482/Eppendorf_Liquid-Handling_Xplorer-Plus-Software-Update-Tool_lab-scene.jpg?imwidth=920)
Move It® Adjustable Tip Spacing Pipettes: Product Video
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/ZmRld4ryPfU/hqdefault.jpg)
How to Fill Microplates Faster
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/RmXqbyWYr20/hqdefault.jpg)
Pipetting with Eppendorf Xplorer® (plus) Pipettes
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/eCuvb6i09io/hqdefault.jpg)
Automatic Dispensing with Eppendorf Xplorer® (plus) Pipettes
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/GKir4KsJ5TE/hqdefault.jpg)
Pipetting and Mixing with Eppendorf Xplorer® (plus) Pipettes
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/H4iGD7UGiEE/hqdefault.jpg)
Reverse Pipetting with Eppendorf Xplorer® plus Pipettes
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/QIXw96JOdFI/hqdefault.jpg)
Sequential Dispensing with Eppendorf Xplorer® plus Pipettes
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/_GdRE8sVE1Q/hqdefault.jpg)
Multi-aspiration with Eppendorf Xplorer® plus Pipettes
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/l1Iumu5Y_Xw/hqdefault.jpg)
Custom Protocols with Eppendorf Xplorer® plus Pipettes
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/ga6KVjgcSpE/hqdefault.jpg)
Temporary Adjustment of Eppendorf Xplorer® (plus) Pipettes
Wideo nie może się załadować, ponieważ nie wyrażono zgody na pliki cookie. Zmień swoje
![](https://img.youtube.com/vi/7uS0dMZqcOM/hqdefault.jpg)
Informacje o produkcie
Często przenosisz próbki pomiędzy naczyniami różnych formatów, np. pomiędzy próbkami a płytkami, i potrzebujesz bardziej wydajnego i bezpiecznego rozwiązania? Nowa pipeta Move It z regulacją odległości pomiędzy końcówkami przyspiesza i upraszcza synchroniczne pipetowanie serii próbek. Wyjątkowa konstrukcja bez połączeń rurowych zapewnia większą precyzję i trwałość, a także bezpieczeństwo Użytkownika i próbek.Move It® Adjustable Tip Spacing Pipette
Dalsze materiały do pobrania znajdują sięna dole strony
Produkty (20)
Zestawy i pakiety (4)
Services (11)
Akcesoria (11)
Części zamienne (6)
20 Produkty
|
|
|
|
|
|
|
|
|
|
Pokaż więcej produktów
Informacje o produkcie
Dane techniczne
Zastosowania
Cechy
Eppendorf opracował własną wersję pipet z regulacją odległości pomiędzy końcówkami, spełniającą nasze najwyższe standardy. Move It to odpowiedź na wymagania Klientów w zakresie skutecznego i bezpiecznego, synchronicznego pipetowania serii próbek pomiędzy różnymi formatami naczyń, np. pomiędzy probówkami a płytkami. Co sprawia, że nowa pipeta Move It jest tak wyjątkowa? Nie zawiera ona żadnych połączeń rurowych pomiędzy stożkiem a układem tłok-cylinder. Pozwala to znacząco zwiększyć wydajność pipetowania: Mniejsza liczba ruchomych, często wrażliwych, elementów oznacza większą precyzję i trwałość. Move It jest autoklawowalna, co zwiększa bezpieczeństwo Użytkownika i próbek.
![Quickly move samples across different vessel formats – with ease! Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=920)
![Quickly move samples across different vessel formats – with ease! Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=540)
Jedna pipeta – Wiele formatów
Pipety wielokanałowe Move It z regulacją odstępów pomiędzy końcówkami znacząco przyspieszają i upraszczają procesy, w których konieczna jest częsta zmiana formatu. Możesz teraz przenosić serię próbek synchronicznie pomiędzy różnymi formatami naczyń, np. pomiędzy probówkami a płytkami. Znacząco skraca to czas pracy w porównaniu do pipet jednokanałowych. W przypadku mikropłytek, probówek i żeli agarozowych można dowolnie dostosowywać odległości pomiędzy stożkami w zakresie od 4,5 do 33 mm, w zależności od modelu.
![Quickly move samples across different vessel formats – with ease! Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=920)
![Quickly move samples across different vessel formats – with ease! Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=540)
![Choose Move It® pipettes with a minimum cone spacing of 4.5 mm when working with 384-well plates Scientist using a Move It_REG_ adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=920)
![Choose Move It® pipettes with a minimum cone spacing of 4.5 mm when working with 384-well plates Scientist using a Move It_REG_ adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=540)
Save up to 70 % of your time when filling 384-well plates
One of the most efficient ways to manually fill a 384-well plate* is a combination of liquid medium distribution with an Eppendorf Xplorer plus 24-channel pipette and synchronous sample transfer with the Xplorer plus Move It pipette. Ask your sales representative for demo devices and see for yourself!
*results were measured by using 12-channel mechanical pipettes for liquid medium distribution and single-channel pipettes for individual sample transfers.
![Choose Move It® pipettes with a minimum cone spacing of 4.5 mm when working with 384-well plates Scientist using a Move It_REG_ adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=920)
![Choose Move It® pipettes with a minimum cone spacing of 4.5 mm when working with 384-well plates Scientist using a Move It_REG_ adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=540)
![Move It® adjustable tip spacing pipettes from Eppendorf feature a quick spacing control Adjustment knob for setting the tip distance with adjustable tip spacing pipette](/product-media/img/global/862413/Eppendorf_Liquid-Handling_Move-It_illustration.jpg?imwidth=920)
![Move It® adjustable tip spacing pipettes from Eppendorf feature a quick spacing control Adjustment knob for setting the tip distance with adjustable tip spacing pipette](/product-media/img/global/862413/Eppendorf_Liquid-Handling_Move-It_illustration.jpg?imwidth=540)
Łatwa i szybka regulacja odległości pomiędzy końcówkami
Format źródłowy i docelowy można ustawić i zablokować za pomocą ogranicznika formatu, co umożliwia szybkie, dwustronne przełączanie pomiędzy ustawionymi formatami. Dzięki temu ustawienie następnego kroku pipetowania nie wymaga dużego skupienia, co oszczędza Twój cenny czas. Dostosowywanie formatu odbywa się ręcznie za pomocą pokrętła, dzięki czemu przebiega szybciej niż regulacja z użyciem silnika. Proces dostosowywania formatu umożliwia zachowanie wygodnej pozycji ciała i dłoni.
![Move It® adjustable tip spacing pipettes from Eppendorf feature a quick spacing control Adjustment knob for setting the tip distance with adjustable tip spacing pipette](/product-media/img/global/862413/Eppendorf_Liquid-Handling_Move-It_illustration.jpg?imwidth=920)
![Move It® adjustable tip spacing pipettes from Eppendorf feature a quick spacing control Adjustment knob for setting the tip distance with adjustable tip spacing pipette](/product-media/img/global/862413/Eppendorf_Liquid-Handling_Move-It_illustration.jpg?imwidth=540)
![Increase precision, accuracy, and durability with our adjustable tip spacing multichannel pipette Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=920)
![Increase precision, accuracy, and durability with our adjustable tip spacing multichannel pipette Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=540)
System pozbawiony rurek jest niezawodny i bezpieczny
Rozwiązanie Eppendorf: Pipeta wielokanałowa Move Itz regulacją odległości pomiędzy końcówkami nie zawiera żadnych rurek łączących stożki z układem tłok-cylinder. Taka konstrukcja oferuje specjalne zalety w porównaniu do konwencjonalnych urządzeń:
• Nie występują problemy związane z obecnością rurek, takie jak porowatość i przecieki. Mniejsza liczba elementów ruchomych w pipetach wielokanałowych Move It sprzyja zwiększonej precyzji i trwałości
• Eliminacja rurek pozwala ograniczyć do minimum rozmiar poduszek powietrznych i ma dalszy pozytywny wpływ na precyzję i dokładność
• Move It można autoklawować (Research plus w całości, w przypadku Xplorer plus tylko dolną część), co dodatkowo zwiększa bezpieczeństwo Użytkownika i próbek
![Increase precision, accuracy, and durability with our adjustable tip spacing multichannel pipette Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=920)
![Increase precision, accuracy, and durability with our adjustable tip spacing multichannel pipette Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=540)
![360° rotation of adjustable tip spacing multi-channel pipette head possible Adjustable tip spacing multichannel pipette head rotatable by 360 degrees](/product-media/img/global/838582/Eppendorf_Liquid-Handling_MoveIt-360-rotatable-pipette-head_illustration.jpg?imwidth=920)
![360° rotation of adjustable tip spacing multi-channel pipette head possible Adjustable tip spacing multichannel pipette head rotatable by 360 degrees](/product-media/img/global/838582/Eppendorf_Liquid-Handling_MoveIt-360-rotatable-pipette-head_illustration.jpg?imwidth=540)
Obrotowa głowica pipety – 360°
Lepsza ergonomia miejsca pracy pozwala zwiększyć płynność procedur roboczych. Ponieważ pipety wielokanałowe Move It z regulacją odległości pomiędzy końcówkami nie zawierają żadnych wewnętrznych rurek, głowica pipety może się obracać o 360°. Dzięki temu Użytkownik może wygodnie odczytywać wyświetlacz. Ma to znaczenie nie tylko dla ergonomicznej i rozluźnionej postawy ciała. Jednocześnie umożliwia to szybkie sprawdzanie wszystkich parametrów, co oszczędza Twój cenny czas.
![360° rotation of adjustable tip spacing multi-channel pipette head possible Adjustable tip spacing multichannel pipette head rotatable by 360 degrees](/product-media/img/global/838582/Eppendorf_Liquid-Handling_MoveIt-360-rotatable-pipette-head_illustration.jpg?imwidth=920)
![360° rotation of adjustable tip spacing multi-channel pipette head possible Adjustable tip spacing multichannel pipette head rotatable by 360 degrees](/product-media/img/global/838582/Eppendorf_Liquid-Handling_MoveIt-360-rotatable-pipette-head_illustration.jpg?imwidth=540)
![Balancing adjustable tip spacing pipette in your daily routine Ergonomic adjustable pipette for daily lab work](/product-media/img/global/838583/Eppendorf_Liquid-Handling_MoveIt-Balance_illustration.jpg?imwidth=920)
![Balancing adjustable tip spacing pipette in your daily routine Ergonomic adjustable pipette for daily lab work](/product-media/img/global/838583/Eppendorf_Liquid-Handling_MoveIt-Balance_illustration.jpg?imwidth=540)
Optymalne wyważenie umożliwia rozluźnienie dłoni
Regulowane pipety Move It dodatkowo minimalizują obciążenie dłoni i reszty ciała. Zachęceni badaniem wykazującym, że dla użytkownika ważniejsze jest dobre wyważenie niż całkowity ciężar, inżynierowie z Eppendorf opracowali specjalną koncepcję konstrukcyjną. Niektóre elementy wewnętrzne pipety zostały zastąpione elementami metalowymi. W rezultacie uzyskano dobrze wyważoną i ergonomiczną pipetę. Dzięki temu końcówki i próbki są zawsze dobrze widoczne, bez wysiłku fizycznego.
![Balancing adjustable tip spacing pipette in your daily routine Ergonomic adjustable pipette for daily lab work](/product-media/img/global/838583/Eppendorf_Liquid-Handling_MoveIt-Balance_illustration.jpg?imwidth=920)
![Balancing adjustable tip spacing pipette in your daily routine Ergonomic adjustable pipette for daily lab work](/product-media/img/global/838583/Eppendorf_Liquid-Handling_MoveIt-Balance_illustration.jpg?imwidth=540)
![epT.I.P.S.® 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces epT.I.P.S._REG_ 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces](/product-media/img/global/561780/Eppendorf_Liquid-Handling_epTIPS-384-20uL_epTIPS-384-20uL_illustration.jpg?imwidth=920)
![epT.I.P.S.® 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces epT.I.P.S._REG_ 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces](/product-media/img/global/561780/Eppendorf_Liquid-Handling_epTIPS-384-20uL_epTIPS-384-20uL_illustration.jpg?imwidth=540)
epT.I.P.S.® 384 with SoftAttach® technology for Move It 20 µL and 100 µL variants
The innovative epT.I.P.S. 384 tips for Move It pipette models with nominal volumes of 20 or 100 µL are equipped with elastic forming groves. These allow the tips to stretch as much as the shape of the tip cone predefines. Meanwhile, the tip attachment and ejection forces are greatly reduced. With this latest expression of the Eppendorf PhysioCare Concept, this system enables a perfect tip seal while operating forces are reduced to a minimum.
Your benefits:
• Reliable tip fit and tightness
• Smooth and even tip attachment
• Tip attachment forces reduced by up to 40 % per cone compared to standard tips
• Reduced ejection forces
• Perfect tip alignment due to extraordinary coaxiality for safe plate maneuvering and liquid transfer
• Extremely fine tip shape
![epT.I.P.S.® 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces epT.I.P.S._REG_ 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces](/product-media/img/global/561780/Eppendorf_Liquid-Handling_epTIPS-384-20uL_epTIPS-384-20uL_illustration.jpg?imwidth=920)
![epT.I.P.S.® 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces epT.I.P.S._REG_ 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces](/product-media/img/global/561780/Eppendorf_Liquid-Handling_epTIPS-384-20uL_epTIPS-384-20uL_illustration.jpg?imwidth=540)
![Choose the right adjustable tip spacing Move It pipette for your application. Table for choosing the right adjustable tip spacing pipette depending on the liquid handling application](/product-media/img/global/884428/Eppendorf_Liquid-Handling_Move-It_selection-guide.jpg?imwidth=920)
![Choose the right adjustable tip spacing Move It pipette for your application. Table for choosing the right adjustable tip spacing pipette depending on the liquid handling application](/product-media/img/global/884428/Eppendorf_Liquid-Handling_Move-It_selection-guide.jpg?imwidth=540)
Poradnik Move It
Korzystając z poradnika, w mgnieniu oka dobierzesz prawidłową pipetę do każdego zastosowania. Wybierz format źródłowy i docelowy zgodnie z planowanym zastosowaniem, a następnie wybierz najbardziej pasującą liczbę kanałów i wariant objętościowy. Każdy z wariantów jest dostępny w wersji Research plus lub elektronicznej pipety Xplorer plus.
Dodatkowe zalety wariantów Xplorer plus Move It
W porównaniu do pipet mechanicznych pipety elektroniczne mają wiele zalet przydatnych w różnych zastosowaniach. Najważniejsze korzyści z używania pipet elektronicznych: zwiększona ergonomia ze względu na prawie zerową siłę wymaganą do obsługi, wyższa precyzja i odtwarzalność oraz inne udogodnienia, takie jak różne tryby pracy (np. pipetowanie i dozowanie za pomocą tylko jednego narzędzia). Oprócz tego urządzenia elektroniczne stanowią fundament cyfrowych rozwiązań laboratoryjnych pozwalających obsługiwać różnorodne rodzaje cieczy i ułatwiających współpracę z innymi laboratoriami oraz tworzenie dokumentacji. Za pomocą narzędzia Eppendorf do aktualizacji oprogramowania pipet możesz łatwo aktualizować swoje pipety elektroniczne i korzystać z najnowszych ulepszeń oprogramowania i dodatkowych funkcji! Dalsze informacje są dostępne na specjalnej stronie internetowej Eppendorf dotyczącej pipetowania elektronicznego.
![Choose the right adjustable tip spacing Move It pipette for your application. Table for choosing the right adjustable tip spacing pipette depending on the liquid handling application](/product-media/img/global/884428/Eppendorf_Liquid-Handling_Move-It_selection-guide.jpg?imwidth=920)
![Choose the right adjustable tip spacing Move It pipette for your application. Table for choosing the right adjustable tip spacing pipette depending on the liquid handling application](/product-media/img/global/884428/Eppendorf_Liquid-Handling_Move-It_selection-guide.jpg?imwidth=540)
Przeczytaj więcej
Przeczytaj mniej
Specyfikacje | Eppendorf Xplorer® plus Move It® - 4861000781 | Eppendorf Research® plus Move It® - 3125000117 | Eppendorf Xplorer® plus Move It® - 4861000782 | Eppendorf Research® plus Move It® - 3125000125 | Eppendorf Xplorer® plus Move It® - 4861000794 | Eppendorf Research® plus Move It® - 3125000133 | Eppendorf Research® plus Move It® - 3125000141 | Eppendorf Xplorer® plus Move It® - 4861000795 | Eppendorf Xplorer® plus Move It® - 4861000816 | Eppendorf Xplorer® plus Move It® - 4861000817 | Eppendorf Xplorer® plus Move It® - 4861000818 | Eppendorf Research® plus Move It® - 3125000150 | Eppendorf Research® plus Move It® - 3125000168 | Eppendorf Research® plus Move It® - 3125000176 | Eppendorf Xplorer® plus Move It® - 4861000833 | Eppendorf Xplorer® plus Move It® - 4861000834 | Eppendorf Xplorer® plus Move It® - 4861000835 | Eppendorf Research® plus Move It® - 3125000184 | Eppendorf Research® plus Move It® - 3125000192 | Eppendorf Research® plus Move It® - 3125000206 |
---|
Rodzaj produktu | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety | Pipety |
Rodzaj pipetowania | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej | System poduszki powietrznej |
Liczba kanałów | 8-kanał | 8-kanał | 12-kanał | 12-kanał | 8-kanał | 8-kanał | 12-kanał | 12-kanał | 4-kanał | 6-kanał | 8-kanał | 4-kanał | 6-kanał | 8-kanał | 4-kanał | 6-kanał | 8-kanał | 4-kanał | 6-kanał | 8-kanał |
Zakres objętości | 1 – 20 µL | 1 – 20 µL | 1 – 20 µL | 1 – 20 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 15 – 300 µL | 15 – 300 µL | 15 – 300 µL | 30 – 300 µL | 30 – 300 µL | 30 – 300 µL | 50 – 1 200 µL | 50 – 1 200 µL | 50 – 1 200 µL | 120 – 1 200 µL | 120 – 1 200 µL | 120 – 1 200 µL |
Color code | jasnoróżowy | jasnoróżowy | jasnoróżowy | jasnoróżowy | jasnożółty | jasnożółty | jasnożółty | jasnożółty | pomarańczowy | pomarańczowy | pomarańczowy | pomarańczowy | pomarańczowy | pomarańczowy | zielony | zielony | zielony | ciemnozielony | ciemnozielony | ciemnozielony |
Skok objętości | 0,02 µL | 0,02 µL | 0,02 µL | 0,02 µL | 0,1 µL | 0,1 µL | 0,1 µL | 0,1 µL | 0,02 µL | 0,02 µL | 0,02 µL | 0,1 µL | 0,1 µL | 0,1 µL | 1,0 µL | 1,0 µL | 1,0 µL | 1 µL | 1 µL | 1 µL |
Tryb pracy | elektroniczny | mechaniczny | elektroniczny | mechaniczny | elektroniczny | mechaniczny | mechaniczny | elektroniczny | elektroniczny | elektroniczny | elektroniczny | mechaniczny | mechaniczny | mechaniczny | elektroniczny | elektroniczny | elektroniczny | mechaniczny | mechaniczny | mechaniczny |
Z Pipette Manager | tak | − | tak | − | tak | − | − | tak | tak | tak | tak | − | − | − | tak | tak | tak | − | − | − |
Języki wyświetlacza | 9 języków | − | 9 języków | − | 9 języków | − | − | 9 języków | 9 języków | 9 języków | 9 języków | − | − | − | 9 języków | 9 języków | 9 języków | − | − | − |
Sprężynujący stożek końcowy | tak | tak | tak | tak | tak | tak | tak | tak | nie | nie | nie | nie | nie | nie | nie | nie | nie | nie | nie | nie |
Przypadkowy błąd pomiaru |
1 µL: ± 8%; ± 0,08 µL 2 µL: ± 5%; ± 0,1 µL 10 µL: ± 2%; ± 0,2 µL 20 µL: ± 1%; ± 0,2 µL |
1 µL: ± 8%; ± 0,08 µL 2 µL: ± 5%; ± 0,1 µL 10 µL: ± 2%; ± 0,2 µL 20,0 µL: ± 1%; ± 0,2 µL |
1 µL: ± 8%; ± 0,08 µL 2 µL: ± 5%; ± 0,1 µL 10 µL: ± 2%; ± 0,2 µL 20 µL: ± 1%; ± 0,2 µL |
1 µL: ± 8%; ± 0,08 µL 2 µL: ± 5%; ± 0,1 µL 10 µL: ± 2%; ± 0,2 µL 20 µL: ± 1%; ± 0,2 µL |
5 µL: ± 4%; ± 0,2 µL 10 µL: ± 2%; ± 0,2 µL 50 µL: ± 0,8%; ± 0,4 µL 100 µL: ± 0,6%; ± 0,6 µL |
5 µL: ± 4%; ± 0,2 µL 10 µL: ± 2%; ± 0,2 µL 50 µL: ± 0,8%; ± 0,4 µL 100 µL: ± 0,6%; ± 0,6 µL |
5 µL: ± 4%; ± 0,2 µL 10 µL: ± 2%; ± 0,2 µL 50 µL: ± 0,008%; ± 0,4 µL 100 µL: ± 0,6%; ± 0,6 µL |
5 µL: ± 4%; ± 0,2 µL 10 µL: ± 2%; ± 0,2 µL 50 µL: ± 0,8%; ± 0,4 µL 100 µL: ± 0,6%; ± 0,6 µL |
15 µL: ± 2%; ± 0,3 µL 30 µL: ± 1%; ± 0,3 µL 150 µL: ± 0,5%; ± 0,75 µL 300 µL: ± 0,25%; ± 0,75 µL |
15 µL: ± 2%; ± 0,3 µL 30 µL: ± 1%; ± 0,3 µL 150 µL: ± 0,5%; ± 0,75 µL 300 µL: ± 0,25%; ± 0,75 µL |
15 µL: ± 2%; ± 0,3 µL 30 µL: ± 1%; ± 0,3 µL 150 µL: ± 0,5%; ± 0,75 µL 300 µL: ± 0,25%; ± 0,75 µL |
15 µL: ± 2%; ± 0,3 µL 30 µL: ± 1,8%; ± 0,5 µL 150 µL: ± 0,6%; ± 0,9 µL 300 µL: ± 0,6%; ± 1,8 µL |
15 µL: ± 2%; ± 0,3 µL 30 µL: ± 1,8%; ± 0,5 µL 150 µL: ± 0,6%; ± 0,9 µL 300 µL: ± 0,6%; ± 1,8 µL |
15 µL: ± 2%; ± 0,3 µL 30 µL: ± 1,8%; ± 0,5 µL 150 µL: ± 0,6%; ± 0,9 µL 300 µL: ± 0,6%; ± 1,8 µL |
50 µL: ± 1,2%; ± 0,6 µL 120 µL: ± 0,9%; ± 1,08 µL 600 µL: ± 0,4%; ± 0,24 µL 1200 µL: ± 0,3%; ± 3,6 µL |
50 µL: ± 1,2%; ± 0,6 µL 120 µL: ± 0,9%; ± 1,08 µL 600 µL: ± 0,4%; ± 0,24 µL 1200 µL: ± 0,3%; ± 3,6 µL |
50 µL: ± 1,2%; ± 0,6 µL 120 µL: ± 0,9%; ± 1,08 µL 600 µL: ± 0,4%; ± 0,24 µL 1200 µL: ± 0,3%; ± 3,6 µL |
50 µL: ± 2%; ± 1 µL 120 µL: ± 1,3%; ± 1,6 µL 600 µL: ± 0,4%; ± 2,4 µL 1200 µL: ± 0,3%; ± 3,6 µL |
50 µL: ± 2%; ± 1 µL 120 µL: ± 1,3%; ± 1,6 µL 600 µL: ± 0,4%; ± 2,4 µL 1200 µL: ± 0,3%; ± 3,6 µL |
50 µL: ± 2%; ± 1 µL 120 µL: ± 1,3%; ± 1,6 µL 600 µL: ± 0,4%; ± 2,4 µL 1200 µL: ± 0,3%; ± 3,6 µL |
Błąd systematyczny pomiaru |
1 µL: ± 12%; ± 0,12 µL 2 µL: ± 8%; ± 0,16 µL 10 µL: ± 4%; ± 0,4 µL 20 µL: ± 2%; ± 0,4 µL |
1 µL: ± 15%; ± 0,15 µL 2 µL: ± 10%; ± 0,2 µL 10 µL: ± 4%; ± 0,4 µL 20,0 µL: ± 2%; ± 0,4 µL |
1 µL: ± 12%; ± 0,12 µL 2 µL: ± 8%; ± 0,16 µL 10 µL: ± 4%; ± 0,4 µL 20 µL: ± 2%; ± 0,4 µL |
1 µL: ± 15%; ± 0,15 µL 2 µL: ± 10%; ± 0,2 µL 10 µL: ± 4%; ± 0,4 µL 20 µL: ± 2%; ± 0,4 µL |
5 µL: ± 6%; ± 0,3 µL 10 µL: ± 3%; ± 0,3 µL 50 µL: ± 1,2%; ± 0,6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0,3 µL 10 µL: ± 3%; ± 0,3 µL 50 µL: ± 1,2%; ± 0,6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0,3 µL 10 µL: ± 3%; ± 0,3 µL 50 µL: ± 1,2%; ± 0,6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0,3 µL 10 µL: ± 3%; ± 0,3 µL 50 µL: ± 1,2%; ± 0,6 µL 100 µL: ± 1%; ± 1 µL |
15 µL: ± 6%; ± 0,9 µL 30 µL: ± 3%; ± 0,9 µL 150 µL: ± 1%; ± 1,5 µL 300 µL: ± 0,6%; ± 1,8 µL |
15 µL: ± 6%; ± 0,9 µL 30 µL: ± 3%; ± 0,9 µL 150 µL: ± 1%; ± 1,5 µL 300 µL: ± 0,6%; ± 1,8 µL |
15 µL: ± 6%; ± 0,9 µL 30 µL: ± 3%; ± 0,9 µL 150 µL: ± 1%; ± 1,5 µL 300 µL: ± 0,6%; ± 1,8 µL |
15 µL: ± 7,4%; ± 1,1 µL 30 µL: ± 3,7%; ± 1,1 µL 150 µL: ± 1%; ± 1,5 µL 300 µL: ± 0,7%; ± 2,1 µL |
15 µL: ± 7,4%; ± 1,1 µL 30 µL: ± 3,7%; ± 1,1 µL 150 µL: ± 1%; ± 1,5 µL 300 µL: ± 0,7%; ± 2,1 µL |
15 µL: ± 7,4%; ± 1,1 µL 30 µL: ± 3,7%; ± 1,1 µL 150 µL: ± 1%; ± 1,5 µL 300 µL: ± 0,7%; ± 2,1 µL |
50 µL: ± 8%; ± 4 µL 120 µL: ± 6%; ± 7,2 µL 600 µL: ± 2,7%; ± 16,2 µL 1200 µL: ± 1,2%; ± 14,4 µL |
50 µL: ± 8%; ± 5 µL 120 µL: ± 6%; ± 7,2 µL 600 µL: ± 2,7%; ± 16,2 µL 1200 µL: ± 1,2%; ± 14,4 µL |
50 µL: ± 8%; ± 6 µL 120 µL: ± 6%; ± 7,2 µL 600 µL: ± 2,7%; ± 16,2 µL 1200 µL: ± 1,2%; ± 14,4 µL |
50 µL: ± 14,5%; ± 7,25 µL 120 µL: ± 6%; ± 7,2 µL 600 µL: ± 2,7%; ± 16,2 µL 1200 µL: ± 1,2%; ± 14,4 µL |
50 µL: ± 14,5%; ± 7,25 µL 120 µL: ± 6%; ± 7,2 µL 600 µL: ± 2,7%; ± 16,2 µL 1200 µL: ± 1,2%; ± 14,4 µL |
50 µL: ± 14,5%; ± 7,25 µL 120 µL: ± 6%; ± 7,2 µL 600 µL: ± 2,7%; ± 16,2 µL 1200 µL: ± 1,2%; ± 14,4 µL |
Autoklawowalne | tak (dolna część) | tak | tak (dolna część) | tak | tak (dolna część) | tak | tak | tak (dolna część) | tak (dolna część) | tak (dolna część) | tak (dolna część) | tak | tak | tak | tak (dolna część) | tak (dolna część) | tak (dolna część) | tak | tak | tak |
Zasilanie elektryczne | 100 – 240 V ±10 %, 50 – 60 Hz | − | 100 – 240 V ±10 %, 50 – 60 Hz | − | 100 – 240 V ±10 %, 50 – 60 Hz | − | − | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | − | − | − | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | − | − | − |
Typ baterii | Akumulator litowo-polimerowy | − | Akumulator litowo-polimerowy | − | Akumulator litowo-polimerowy | − | − | Akumulator litowo-polimerowy | Akumulator litowo-polimerowy | Akumulator litowo-polimerowy | Akumulator litowo-polimerowy | − | − | − | Akumulator litowo-polimerowy | Akumulator litowo-polimerowy | Akumulator litowo-polimerowy | − | − | − |
Consumables | tylko epT.I.P.S.® 384 | tylko epT.I.P.S.® 384 | tylko epT.I.P.S.® 384 | tylko epT.I.P.S.® 384 | tylko epT.I.P.S.® 384 | tylko epT.I.P.S.® 384 | tylko epT.I.P.S.® 384 | tylko epT.I.P.S.® 384 | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® |
Otwarty system (materiały zużywalne innych producentów) | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak | tak |
Zawartość dostawy | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat | Pipeta, końcówki do pipet epT.I.P.S.® Box 2.0, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5) | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat | Pipeta, końcówki do pipet epT.I.P.S.® Box 2.0, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5) | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat | Pipeta, końcówki do pipet epT.I.P.S.® Box 2.0, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5) | Pipeta, końcówki do pipet epT.I.P.S.® Box 2.0, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5) | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat, narzędzie do pierścieni uszczelniających | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat, narzędzie do pierścieni uszczelniających | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat, narzędzie do pierścieni uszczelniających | Pipeta, końcówki do pipet epT.I.P.S.® Box 2.0, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5), narzędzie do pierścieni uszczelniających | Pipeta, końcówki do pipet epT.I.P.S.® Box 2.0, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5), narzędzie do pierścieni uszczelniających | Pipeta, końcówki do pipet epT.I.P.S.® Box 2.0, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5), narzędzie do pierścieni uszczelniających | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat, narzędzie do odblokowywania, narzędzie do pierścieni uszczelniających | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat, narzędzie do odblokowywania, narzędzie do pierścieni uszczelniających | Pipeta, zasilacz sieciowy z adapterami wtyczki, instrukcja obsługi, instrukcja skrócona, certyfikat, narzędzie do odblokowywania, narzędzie do pierścieni uszczelniających | Pipeta, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5), narzędzie do odblokowywania, narzędzie do pierścieni uszczelniających | Pipeta, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5), narzędzie do odblokowywania, narzędzie do pierścieni uszczelniających | Pipeta, instrukcja obsługi, certyfikat, narzędzie do regulacji, zaślepka regulacji tymczasowej (x5), narzędzie do odblokowywania, narzędzie do pierścieni uszczelniających |
- Wszystkie warianty:
• ELISA
• Hodowla komórek
• Eksperymenty na komórkach
• (Real time) PCR
• Genotypowanie myszy
• Analiza krwi
• Analiza FACS
• Transfer pożywki
• Rozcieńczenia seryjne
• Badania przesiewowe - Warianty Research plus:
• Pipetowanie proste
• Pipetowanie odwrotne
• Usuwanie nadsączy
• Mieszanie próbki
• Ekstrakcja fazowa
• Napełnianie płytek, żeli i naczyń reakcyjnych - Warianty Xplorer plus:
• Automatyczne pipetowanie cieczy (Pip) do pipetowania prostego
• Pipetowanie manualne (Man) do oznaczania objętości
• Pipetowanie i mieszanie (P/M) do automatycznego mieszania próbek
• Dozowanie (Dis) do manualnego napełniania płytek, żeli i naczyń reakcyjnych
• Dozowanie automatyczne (Ads) do automatycznego napełniania płytek, żeli i naczyń reakcyjnych
• Pobieranie wielokrotne (Spc): Pulowanie nadsączy z różnych naczyń
• Dozowanie sekwencyjne i pipetowanie (Spc) do skoków objętościowych definiowanych przez Użytkownika
• Pipetowanie odwrotne (Spc) do roztworów niewodnych
• Rozcieńczanie (Spc) do wykonywania rozcieńczeń seryjnych
• Stała objętość (Fix): Możliwość zapisu maksymalnie 10 objętości ułatwia pracę
- Pipety z poduszką powietrzną 4, 6, 8 i 12-kanałowe ze zmienną objętością i opcja regulacji odległości pomiędzy końcówkami
- Dostępne w formie pipety mechanicznej (Research plus) lub elektronicznej pipety wielokanałowej (Xplorer plus) z regulacją odstępów pomiędzy końcówkami
- Do płytek (384-, 96-, 48-, 24- i 12-dołkowych), probówek, żeli agarozowych i innych zastosowań (zależnie od wariantu pipety)
- Odległość pomiędzy końcówkami ustawiana dowolnie w zakresie od 4,5 do 33 mm, w zależności od wariantu pipety
- Ogranicznik odstępu umożliwia szybkie, dwustronne przełączanie pomiędzy formatem źródłowym a docelowym
- Manualne pokrętło regulacyjne do płynnego i bezwibracyjnego przełączania formatu oraz przenoszenia cieczy bez kapania
- Układ pozbawiony rurek zwiększa niezawodność i bezpieczeństwo
- Możliwość autoklawowania zapewnia bezpieczeństwo Użytkownika i próbek (Research plus w całości, a w przypadku Xplorer plus tylko dolna część)
- Głowica pipety obracana o 360° zapewnia wygodny odczyt wyświetlacza i szybką identyfikację parametrów
- Optymalne wyważenie pipety - redukuje zmęczenie i obciążenia podczas pracy