MENU
MY | MYR
MY | MYR
-
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- Accessories
- High-Speed and Ultracentrifugation Consumables
- Tubes
- Plates
- Device Management Software
- Sample and Information Management
No results found
Search Suggestions
Eppendorf ThermoMixer® F
Family of Eppendorf ThermoMixer® F series

Different instruments for dedicated vessel sizes
Eppendorf ThermoMixer® F0.5 - 0.5 mL vessels

Eppendorf ThermoMixer F0.5: Optimized instrument for incubation and mixing for 0.5 mL vessels
Eppendorf ThermoMixer®_F1.5 - 1.5 mL vessels

Eppendorf ThermoMixer F1.5: Optimized for routine applications with 1.5 mL vessels
Eppendorf ThermoMixer®_F2.0 - 2.0 mL vessels

Eppendorf ThermoMixer® F2.0: Optimized for routine applications with 2.0 mL vessels
Eppendorf ThermoMixer®_FP - plates

Eppendorf ThermoMixer® FP: Optimized for routine applications with plates
Eppendorf ThermoMixer®_FP - plates

Eppendorf ThermoMixer® FP: Optimized for routine applications with plates
Eppendorf ThermoMixer®_F1.5 with ThermoTop aside

Eppendorf ThermoMixer®_F1.5 with ThermoTop aside
ThermoMixer_F1.5 total angle ThermoTop

Eppendorf ThermoMixer F1.5 with ThermoTop
ThermoMixer_F0.5 total_angle_w_ThermoTop

Even higher sample safety can be reached by using the ThermoTop: Additional heat reduces potential condensation within the vessel lids
Reliable experiments by condens.protect®
Videos not loading, because cookies have been rejected. Change your

Pellet resuspension
Videos not loading, because cookies have been rejected. Change your

Product Information
Doing a lot of routine mixing and heating?These products are the perfect choice for mixing and heating established routine applications. The Eppendorf ThermoMixer F0.5/F1.5/F2.0 and FP have a fixed block for 0.5/1.5/2.0 mL tubes and plates, respectively. Reliable prevention of condensate formation in small vessels can be achieved with the heated lid Eppendorf ThermoTop (optional).

Thermo-Mixer-F2-0
You will find additional download material at the bottom of this page
Products (4)
Services (10)
Accessories (3)
VisioNize (2)
4 Products
Catalog no.
5384000039
|
Catalog no.
5385000032
|
Catalog no.
5386000036
|
Catalog no.
5387000030
|
Show more Products
Added to Your Cart
Product Information
Technical Data
Applications
Features
Product Information
Doing quite routine sample prep steps? Wether you regularly work with 0.5/1.5/2.0 mL vessels or plates (MTP and DWP) - our customized fixed-block Eppendorf ThermoMixer F family offers you a good solution for your special application. Just simplify your routine work load.


Facing irregular mixing results?
Reliable sample mixing is far beyond simple mixing, especially when talking about microliter volumes. After decades of offering mixing devices, we found a way to expand reliable mixing performance to the microliter scale:




2DMix–Control
The 2DMix–Control technology mixes liquids in a controlled, circular movement. Orbital circular paths with a diameter of 3 mm and up to 3,000 rpm: Generates excellent mixing performance, even for challenging samples. The ThermoMixer provides enough mixing power to handle also challenging mixing tasks. Most samples are efficiently mixed within less than a minute independent of vessel geometry or sample properties.




Tired of condensation in your tubes?
We combined the Eppendorf ThermoMixer with the PCR cycler approach of a heated lid and generated the Eppendorf ThermoTop®. The outstanding Eppendorf condens.protect technology reliably prevents condensation within the tube lid – sample concentrations are consistent for the incubation time.
In addition, the temperature homogeneity is further improved. Get optimal sample reaction conditions to produce optimal results.
• Efficient and reliable condensation prevention on tube lids for safe sample heating
• Get constant reaction conditions for optimal enzymatic performance within your sample
• Wireless connection with automatic recognition and operation for user-friendly handling




Missing a second temperature for an incubation at 37 °C or 95 °C at your Eppendorf ThermoMixer?
The Eppendorf SmartExtender offers a comfortable incubation tool which can easily be used as an add-on to your existing Eppendorf SmartBlocks and the Eppendorf ThermoMixer C/Fx as well as Eppendorf ThermoStat C. Up to 12 vessels (1.5 mL) can be heated up for a higher throughput and higher flexibility in your lab. The independent heating function for the second temperature enables a parallel usage of an Eppendorf SmartBlock and the SmartExtender. The Eppendorf SmartBlock at the center can still be used for heating and mixing.




Struggling with paper-based documentation?
The eLabJournal Electronic Lab Notebook offers an intuitive and flexible solution to document research and track research data like workflow processes where the Eppendorf ThermoMixer is involved. Improve efficiency when documenting, organizing, searching, and archiving collected data. With the free eLabJournal add-ons, you can extend the functionality of eLabJournal to a fully integrated Laboratory Information Management System.
Start a free 30-day trial!
Visit www.eLabJournal.com




Efficient lab and device management with VisioNize® Lab Suite
Are you interested in monitoring your lab devices and receiving notifications e.g., for device alarms? A digital, connected lab offers even more.
Gain access to a modular range of digital services and choose what works for your lab. VisioNize Lab Suite offers everything you need as a Lab Manager or Scientist to get started to digitally manage your lab for increased sample security, compliance needs and maintenance management.
Chart your own course to digital lab excellence! Find out more


Read More
Read Less
Technical Data
Specifications | Eppendorf ThermoMixer® F1.5 | Eppendorf ThermoMixer® FP | Eppendorf ThermoMixer® F0.5 | Eppendorf ThermoMixer® F2.0 |
---|
Product type | ThermoMixer | ThermoMixer | ThermoMixer | ThermoMixer |
Interfaces | USB interface | USB interface | USB interface | USB interface |
Power supply | 220 – 240 V, 50 – 60 Hz | 220 – 240 V, 50 – 60 Hz | 200 – 240 V, 50 – 60 Hz | 220 – 240 V, 50 – 60 Hz |
Max. power consumption | 200 W | 200 W | 200 W | 200 W |
Dimensions (W × D × H) | 20.6 × 30.4 × 17.0 cm / 8.1 × 11.9 × 6.7 in | 20.6 × 30.4 × 16.4 cm / 8.1 × 11.9 × 6.4 in | 20.6 × 30.4 × 16.3 cm / 8.1 × 1.9 × 6.4 in | 20.6 × 30.4 × 17.0 cm / 8.1 × 11.9 × 6.7 in |
Product weight | 6.3 kg / 13.9 lb | 6.1 kg / 13.4 lb | 6.2 kg / 13.6 lb | 6.3 kg / 13.9 lb |
Max. speed | 1,500 rpm | 2,000 rpm | 2,000 rpm | 1,500 rpm |
Temperature range | Min: 4 °C above RT, max: 100 °C | Min: 4 °C above RT, max: 100 °C | Min: 4 °C above RT, max: 100 °C | Min: 4 °C above RT, max: 100 °C |
Mixing frequency | 300 – 1,500 rpm | 300 – 2,000 rpm | 300 – 2,000 rpm | 300 – 1,500 rpm |
Mixing and vortexing radius | 1.5 mm | 1.5 mm | 1.5 mm | 1.5 mm |
Temperature settings | 1 °C / 100 °C | 1 °C / 100 °C | 1 °C / 100 °C | 1 °C / 100 °C |
Mixing orbit | 3 mm | 3 mm | 3 mm | 3 mm |
Temperature accuracy | Max. ±0.5 °C at 20 – 45 °C | Max. ±0.5 °C at 20 – 45 °C | Max. ±0.5 °C at 20 – 45 °C | Max. ±0.5 °C at 20 – 45 °C |
Eppendorf ThermoMixer® |
||||
Heating rate | Max. 11 °C/min | Max. 18 °C/min | Max. 15 °C/min | Max. 13 °C/min |
Applications
- Growth of bacteria and yeasts
- Enzymatic reactions
- Transformation of bacteria strains and plasmids
- Denaturation of DNA, RNA, and proteins
- Lysis reactions at 100 °C
- Labeling of nucleic acids and proteins
- Proteinase K digestion of cells and tissues
- Resuspension of pellets
- Mixing protein quantification assays
- ELISA assays
Features
- Heating and mixing in 0.5/1.5/2.0 mL reaction vessels (F0.5/F1.5/F2.0) or plates (FP)
- Up to 1,500 rpm (F1.5/F2.0) or 2,000 rpm (F0.5/FP) for efficient sample mixing
- Outstanding 2DMix-Control technology results in excellent mixing performance
- Anti-spill technology prevents lid wetting and cross-contamination
- Compatible with Eppendorf ThermoTop (condens.protect®) for condensation-free sample handling
- Predefined temperature keys (37 °C, 42 °C, 56 °C, and 95 °C) for simple and intuitive operation
- Very fast heat up speed of up to 18 °C/min, reducing your waiting time
- Eppendorf PhysioCare Concept® provides ergonomic design and operation
Downloads: Eppendorf ThermoMixer® F
-
English