Move It® Adjustable Tip Spacing Pipettes - Adjustable Pipette
Move It® adjustable tip spacing multi-channel pipettes from Eppendorf
![Move It® adjustable tip spacing multi-channel pipettes from Eppendorf Move It® adjustable tip spacing multi-channel pipettes from Eppendorf](/product-media/img/global/813580/Eppendorf_Liquid-Handling_Xplorer-plus-8-channels-1200uL-Research-plus-4-channels-300uL_product.jpg?imwidth=920)
Move It® adjustable tip spacing multi-channel pipettes are the ideal dispensing tool when switching vessel formats
![Move It® adjustable tip spacing multi-channel pipettes are the ideal dispensing tool when switching vessel formats Move It® adjustable tip spacing multi-channel pipettes are the ideal dispensing tool when switching vessel formats](/product-media/img/global/814277/Eppendorf_Liquid-Handling_Research-plus-Multichannel-Pipette-8-channels_key-visual.jpg?imwidth=920)
Quickly move samples across different vessel formats – with ease!
![Quickly move samples across different vessel formats – with ease! Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=920)
Increase precision, accuracy, and durability with our adjustable tip spacing multichannel pipette
![Increase precision, accuracy, and durability with our adjustable tip spacing multichannel pipette Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=920)
1) Research plus variants fully, Xplorer plus lower part only.
Eppendorf Research® plus Move It® 8-channel pipette, 5 – 100 µL, light yellow
![Eppendorf Research® plus Move It® 8-channel pipette, 5 – 100 µL, light yellow Mechanical Eppendorf Research® plus Move It® adjustable tip spacing pipette with 8 channels](/product-media/img/global/780303/Eppendorf_Liquid-Handling_Research-plus-8-channels-100uL_product.jpg?imwidth=920)
Eppendorf Xplorer® plus Move It® 6-channel pipette, 15 – 300 µL, orange
![Eppendorf Xplorer® plus Move It® 6-channel pipette, 15 – 300 µL, orange Eppendorf Xplorer® plus Move It® electronic pipette with 6 adjustable channels](/product-media/img/global/783996/Eppendorf_Liquid-Handling_Xplorer-plus-6-channels-300uL_product.jpg?imwidth=920)
Move It® adjustable tip spacing multi-channel pipettes work without any tubing connections between cone and piston-cylinder system
![Move It® adjustable tip spacing multi-channel pipettes work without any tubing connections between cone and piston-cylinder system Move It® Adjustable Tip Spacing Pipettes: Transparent Lower Part in Action (GIF, Frontal View)](/product-media/doc/global/1119083/Liquid-Handling_Move-It-Animation1_GIF.gif?imwidth=920)
Easily and quickly adjust tip spacing with a manual adjustment knob
![Easily and quickly adjust tip spacing with a manual adjustment knob Move It® Adjustable Tip Spacing Pipettes: Transparent Lower Part in Action (GIF, Side View)](/product-media/doc/global/1119088/Liquid-Handling_Move-It-Animation2_GIF.gif?imwidth=920)
Female Scientist using Eppendorf Research® plus Move It® Pipette for Easy Liquid Transfer Between Vessel Formats
![Female Scientist using Eppendorf Research® plus Move It® Pipette for Easy Liquid Transfer Between Vessel Formats Female Scientist using Eppendorf Research® plus Move It® Pipette for Easy Liquid Transfer Between Vessel Formats](/product-media/img/global/1735384/Eppendorf_Liquid-Handling_Research-plus-Move-It_people-lab-scene.jpg?imwidth=920)
Accelerate and simplify synchronous pipetting of a series of samples and experience a new joy in the lab!
![Accelerate and simplify synchronous pipetting of a series of samples and experience a new joy in the lab! Scientist using a Move It® adjustable tip spacing pipette to transfer liquid from a series of tubes to a plate](/product-media/img/global/763053/Eppendorf_Liquid-Handling_Move-It-handling-scene-5_people-lab-scene.jpg?imwidth=920)
Choose Move It® pipettes with a minimum cone spacing of 4.5 mm when working with 384-well plates
![Choose Move It® pipettes with a minimum cone spacing of 4.5 mm when working with 384-well plates Scientist using a Move It® adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=920)
The software of your Eppendorf Xplorer® plus pipette can easily be updated using the Pipette Software Update Tool
![The software of your Eppendorf Xplorer® plus pipette can easily be updated using the Pipette Software Update Tool The software of your Eppendorf Xplorer® plus pipette can easily be updated using the Pipette Software Update Tool](/product-media/img/global/1075482/Eppendorf_Liquid-Handling_Xplorer-Plus-Software-Update-Tool_lab-scene.jpg?imwidth=920)
Move It® Adjustable Tip Spacing Pipettes: Product Video
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/ZmRld4ryPfU/hqdefault.jpg)
How to Fill Microplates Faster
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/RmXqbyWYr20/hqdefault.jpg)
Pipetting with Eppendorf Xplorer® (plus) Pipettes
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/eCuvb6i09io/hqdefault.jpg)
Automatic Dispensing with Eppendorf Xplorer® (plus) Pipettes
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/GKir4KsJ5TE/hqdefault.jpg)
Pipetting and Mixing with Eppendorf Xplorer® (plus) Pipettes
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/H4iGD7UGiEE/hqdefault.jpg)
Reverse Pipetting with Eppendorf Xplorer® plus Pipettes
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/QIXw96JOdFI/hqdefault.jpg)
Sequential Dispensing with Eppendorf Xplorer® plus Pipettes
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/_GdRE8sVE1Q/hqdefault.jpg)
Multi-aspiration with Eppendorf Xplorer® plus Pipettes
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/l1Iumu5Y_Xw/hqdefault.jpg)
Custom Protocols with Eppendorf Xplorer® plus Pipettes
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/ga6KVjgcSpE/hqdefault.jpg)
Temporary Adjustment of Eppendorf Xplorer® (plus) Pipettes
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/7uS0dMZqcOM/hqdefault.jpg)
Product Information
Do you frequently transfer samples across different vessel formats, such as between tubes and plates, and strive for more efficient and safe solutions? The adjustable tip spacing pipette Move It accelerates and simplifies synchronous pipetting of a series of samples. A unique design without tubing connections results in increased precision and durability as well as user and sample safety.Move It® Adjustable Tip Spacing Pipette
You will find additional download material at the bottom of this page
Single Devices (20)
Services (11)
Accessories (11)
Spare Parts (6)
20 Single Devices
Price
HK$ 29,348.00
|
Price
HK$ 24,743.00
|
Price
HK$ 31,096.00
|
Price
HK$ 26,632.00
|
Price
HK$ 29,348.00
|
Price
HK$ 24,743.00
|
Price
HK$ 26,632.00
|
Price
HK$ 31,096.00
|
Price
HK$ 27,719.00
|
Price
HK$ 28,533.00
|
Show more Products
Product Information
Technical Data
Applications
Features
Double your pipetting performance with adjustable spacer pipettes
Eppendorf redefined adjustable tip spacing pipettes from scratch according to their premium standards. Move It is the result of customer requests for an efficient and safe solution for synchronous pipetting of a series of samples between different vessel formats, such as between tubes and plates. What is unique about the Move It? It can do this without any tubing connections between cone and piston-cylinder system. This significantly enhances pipetting performance: Fewer movable, often fragile parts, means more precision and durability. Move It is autoclavable which increases user and sample safety.
![Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=920)
![Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=540)
One pipette – Many vessel formats
Move It adjustable tip spacing multi-channel pipettes significantly accelerate and simplify the workflow when frequent format changes are required. Let’s get ready to move a series of samples synchronously between different vessel formats, such as between tubes and plates. The operating time is significantly less than when using single-channel pipettes. For microplates, tubes, and agarose gels, the tip spacing can be freely selected between 4.5 and 33 mm depending on the model.
![Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=920)
![Illustration highlighting the transfer of samples from tubes to a 96-well plate or agarose gel](/product-media/img/global/838584/Eppendorf_Liquid-Handling_MoveIt-Application-Efficency_illustration.jpg?imwidth=540)
![Scientist using a Move It® adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=920)
![Scientist using a Move It® adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=540)
Save up to 70 % of your time when filling 384-well plates
One of the most efficient ways to manually fill a 384-well plate* is a combination of liquid medium distribution with an Eppendorf Xplorer plus 24-channel pipette and synchronous sample transfer with the Xplorer plus Move It pipette. Ask your sales representative for demo devices and see for yourself!
*results were measured by using 12-channel mechanical pipettes for liquid medium distribution and single-channel pipettes for individual sample transfers.
![Scientist using a Move It® adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=920)
![Scientist using a Move It® adjustable tip spacing pipette to dispense liquid into a 384-well plate](/product-media/img/global/763061/Eppendorf_Liquid-Handling_Xplorer-Move-It-workflow-scene-1_people-lab-scene.jpg?imwidth=540)
![Adjustment knob for setting the tip distance with adjustable tip spacing pipette](/product-media/img/global/862413/Eppendorf_Liquid-Handling_Move-It_illustration.jpg?imwidth=920)
![Adjustment knob for setting the tip distance with adjustable tip spacing pipette](/product-media/img/global/862413/Eppendorf_Liquid-Handling_Move-It_illustration.jpg?imwidth=540)
Easy and fast tip spacing adjustment
Source and destination formats can be adjusted and locked with the format limiter which quickly switches forward and backward within the set formats. This means less concentration is required when setting the next pipetting step, saving valuable time. The format adjustment itself is carried out manually with an adjustment knob which allows for a quicker adjustment than via a motor. The format adjustment process is designed to allow the user to always maintain a relaxed body and hand position.
![Adjustment knob for setting the tip distance with adjustable tip spacing pipette](/product-media/img/global/862413/Eppendorf_Liquid-Handling_Move-It_illustration.jpg?imwidth=920)
![Adjustment knob for setting the tip distance with adjustable tip spacing pipette](/product-media/img/global/862413/Eppendorf_Liquid-Handling_Move-It_illustration.jpg?imwidth=540)
![Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=920)
![Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=540)
Tubeless adjustable cone system for reliability and safety
The Eppendorf way: Move It adjustable tip spacing multi-channel pipettes work without any tubing connections between cone and piston-cylinder system. This design offers special advantages compared with conventional instruments:
• Potential problems caused by the presence of tubing, such as porosity and leaks, are not an issue here. Instead, fewer moving parts in Move It multi-channel pipettes increase precision and durability
• By eliminating tubing, the size of the air cushions is reduced to a minimum which has an additional positive effect on precision and accuracy
• Move It can be autoclaved (Research plus fully, Xplorer plus lower part only) which additionally increases user and sample-safety
![Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=920)
![Tubing-free connections of cone and piston-cylinder system in adjustable tip spacing multichannel pipette](/product-media/img/global/838585/Eppendorf_Liquid-Handling_MoveIt-Tubeless-S5ystem_illustration.jpg?imwidth=540)
![Adjustable tip spacing multichannel pipette head rotatable by 360 degrees](/product-media/img/global/838582/Eppendorf_Liquid-Handling_MoveIt-360-rotatable-pipette-head_illustration.jpg?imwidth=920)
![Adjustable tip spacing multichannel pipette head rotatable by 360 degrees](/product-media/img/global/838582/Eppendorf_Liquid-Handling_MoveIt-360-rotatable-pipette-head_illustration.jpg?imwidth=540)
Rotatable pipette head – 360°
An ergonomic optimization of your workplace can help to make workflows more streamlined. As Move It adjustable tip spacing multi-channel pipettes are designed without internal tubes, the pipette head is 360° rotatable. The user benefits from comfortable readability of the display. This not only supports an ergonomic and relaxed body posture. At the same time, it ensures fast identification of all parameters saving valuable time at the bench.
![Adjustable tip spacing multichannel pipette head rotatable by 360 degrees](/product-media/img/global/838582/Eppendorf_Liquid-Handling_MoveIt-360-rotatable-pipette-head_illustration.jpg?imwidth=920)
![Adjustable tip spacing multichannel pipette head rotatable by 360 degrees](/product-media/img/global/838582/Eppendorf_Liquid-Handling_MoveIt-360-rotatable-pipette-head_illustration.jpg?imwidth=540)
![Ergonomic adjustable pipette for daily lab work](/product-media/img/global/838583/Eppendorf_Liquid-Handling_MoveIt-Balance_illustration.jpg?imwidth=920)
![Ergonomic adjustable pipette for daily lab work](/product-media/img/global/838583/Eppendorf_Liquid-Handling_MoveIt-Balance_illustration.jpg?imwidth=540)
Optimal balance for a relaxed hand
Furthermore, Move It adjustable pipettes can help minimize hand and body fatigue. Encouraged by a study that showed that a good balance is more important to the user than the overall weight, Eppendorf product engineers have developed a special design concept. They replaced some inner parts of the pipette with metal parts. The result is a well-balanced and ergonomic pipette. It ensures that tips and samples are clearly visible at all times without great physical effort.
![Ergonomic adjustable pipette for daily lab work](/product-media/img/global/838583/Eppendorf_Liquid-Handling_MoveIt-Balance_illustration.jpg?imwidth=920)
![Ergonomic adjustable pipette for daily lab work](/product-media/img/global/838583/Eppendorf_Liquid-Handling_MoveIt-Balance_illustration.jpg?imwidth=540)
![epT.I.P.S.® 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces](/product-media/img/global/561780/Eppendorf_Liquid-Handling_epTIPS-384-20uL_epTIPS-384-20uL_illustration.jpg?imwidth=920)
![epT.I.P.S.® 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces](/product-media/img/global/561780/Eppendorf_Liquid-Handling_epTIPS-384-20uL_epTIPS-384-20uL_illustration.jpg?imwidth=540)
epT.I.P.S.® 384 with SoftAttach® technology for Move It 20 µL and 100 µL variants
The innovative epT.I.P.S. 384 tips for Move It pipette models with nominal volumes of 20 or 100 µL are equipped with elastic forming groves. These allow the tips to stretch as much as the shape of the tip cone predefines. Meanwhile, the tip attachment and ejection forces are greatly reduced. With this latest expression of the Eppendorf PhysioCare Concept, this system enables a perfect tip seal while operating forces are reduced to a minimum.
Your benefits:
• Reliable tip fit and tightness
• Smooth and even tip attachment
• Tip attachment forces reduced by up to 40 % per cone compared to standard tips
• Reduced ejection forces
• Perfect tip alignment due to extraordinary coaxiality for safe plate maneuvering and liquid transfer
• Extremely fine tip shape
![epT.I.P.S.® 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces](/product-media/img/global/561780/Eppendorf_Liquid-Handling_epTIPS-384-20uL_epTIPS-384-20uL_illustration.jpg?imwidth=920)
![epT.I.P.S.® 384 pipette tips are equipped with elastic forming groves, significantly reducing tip attachment and ejection forces](/product-media/img/global/561780/Eppendorf_Liquid-Handling_epTIPS-384-20uL_epTIPS-384-20uL_illustration.jpg?imwidth=540)
![Table for choosing the right adjustable tip spacing pipette depending on the liquid handling application](/product-media/img/global/884428/Eppendorf_Liquid-Handling_Move-It_selection-guide.jpg?imwidth=920)
![Table for choosing the right adjustable tip spacing pipette depending on the liquid handling application](/product-media/img/global/884428/Eppendorf_Liquid-Handling_Move-It_selection-guide.jpg?imwidth=540)
Move It adjustable tip spacing pipettes selection guide
With the selection guide, it is possible to choose the right pipette for every application at a glance. Select source and destination format according to your application and then select the channel and volume-variant best suited to your application. Each variant is available as mechanical Research plus or electronic Xplorer plus Move It pipette.
Additional benefits with the Xplorer plus Move It variants
Compared to mechanical pipettes, electronic pipettes have a number of advantages in many applications. The most important benefits of using an electronic pipette are: better ergonomics by requiring almost no operating forces, a higher precision and reproducibility and an additional efficiency gain due to various operating modes (such as e.g. pipetting and dispensing with only one tool). Furthermore, electronic instruments are the basis for new, digital and connected pipetting solutions supporting you with choosing settings for different liquid types, collaborating across the lab or documenting steps. With the Eppendorf Pipette Software Update Tool you can easily update your electronic pipette and stay up to date with the latest software improvements and new features! Learn more at Eppendorf's dedicated microsite about electronic pipetting.
![Table for choosing the right adjustable tip spacing pipette depending on the liquid handling application](/product-media/img/global/884428/Eppendorf_Liquid-Handling_Move-It_selection-guide.jpg?imwidth=920)
![Table for choosing the right adjustable tip spacing pipette depending on the liquid handling application](/product-media/img/global/884428/Eppendorf_Liquid-Handling_Move-It_selection-guide.jpg?imwidth=540)
Read More
Read Less
Specifications | Eppendorf Xplorer® plus Move It® - 4861000781 | Eppendorf Research® plus Move It® - 3125000117 | Eppendorf Xplorer® plus Move It® - 4861000782 | Eppendorf Research® plus Move It® - 3125000125 | Eppendorf Xplorer® plus Move It® - 4861000794 | Eppendorf Research® plus Move It® - 3125000133 | Eppendorf Research® plus Move It® - 3125000141 | Eppendorf Xplorer® plus Move It® - 4861000795 | Eppendorf Xplorer® plus Move It® - 4861000816 | Eppendorf Xplorer® plus Move It® - 4861000817 | Eppendorf Xplorer® plus Move It® - 4861000818 | Eppendorf Research® plus Move It® - 3125000150 | Eppendorf Research® plus Move It® - 3125000168 | Eppendorf Research® plus Move It® - 3125000176 | Eppendorf Xplorer® plus Move It® - 4861000833 | Eppendorf Xplorer® plus Move It® - 4861000834 | Eppendorf Xplorer® plus Move It® - 4861000835 | Eppendorf Research® plus Move It® - 3125000184 | Eppendorf Research® plus Move It® - 3125000192 | Eppendorf Research® plus Move It® - 3125000206 |
---|
Product type | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes |
Pipetting type | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system |
Number of channels | 8-channel | 8-channel | 12-channel | 12-channel | 8-channel | 8-channel | 12-channel | 12-channel | 4-channel | 6-channel | 8-channel | 4-channel | 6-channel | 8-channel | 4-channel | 6-channel | 8-channel | 4-channel | 6-channel | 8-channel |
Volume range | 1 – 20 µL | 1 – 20 µL | 1 – 20 µL | 1 – 20 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 15 – 300 µL | 15 – 300 µL | 15 – 300 µL | 30 – 300 µL | 30 – 300 µL | 30 – 300 µL | 50 – 1,200 µL | 50 – 1,200 µL | 50 – 1,200 µL | 120 – 1,200 µL | 120 – 1,200 µL | 120 – 1,200 µL |
Color code | light pink | light pink | light pink | light pink | light yellow | light yellow | light yellow | light yellow | orange | orange | orange | orange | orange | orange | green | green | green | dark green | dark green | dark green |
Volume increment | 0.02 µL | 0.02 µL | 0.02 µL | 0.02 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.02 µL | 0.02 µL | 0.02 µL | 0.1 µL | 0.1 µL | 0.1 µL | 1.0 µL | 1.0 µL | 1.0 µL | 1 µL | 1 µL | 1 µL |
Operating mode | electronic | mechanical | electronic | mechanical | electronic | mechanical | mechanical | electronic | electronic | electronic | electronic | mechanical | mechanical | mechanical | electronic | electronic | electronic | mechanical | mechanical | mechanical |
Pipette Manager enabled | yes | − | yes | − | yes | − | − | yes | yes | yes | yes | − | − | − | yes | yes | yes | − | − | − |
Display languages | 9 languages | − | 9 languages | − | 9 languages | − | − | 9 languages | 9 languages | 9 languages | 9 languages | − | − | − | 9 languages | 9 languages | 9 languages | − | − | − |
Spring-loaded tip cone | yes | yes | yes | yes | yes | yes | yes | yes | no | no | no | no | no | no | no | no | no | no | no | no |
Random measurement error |
1 µL: ± 8%; ± 0.08 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 2%; ± 0.2 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 8%; ± 0.08 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 2%; ± 0.2 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 8%; ± 0.08 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 2%; ± 0.2 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 8%; ± 0.08 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 2%; ± 0.2 µL 20 µL: ± 1%; ± 0.2 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.008%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.25%; ± 0.75 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.25%; ± 0.75 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.25%; ± 0.75 µL |
30 µL: ± 1.8%; ± 0.5 µL 150 µL: ± 0.6%; ± 0.9 µL 300 µL: ± 0.6%; ± 1.8 µL |
30 µL: ± 1.8%; ± 0.5 µL 150 µL: ± 0.6%; ± 0.9 µL 300 µL: ± 0.6%; ± 1.8 µL |
30 µL: ± 1.8%; ± 0.5 µL 150 µL: ± 0.6%; ± 0.9 µL 300 µL: ± 0.6%; ± 1.8 µL |
50 µL: ± 1.2%; ± 0.6 µL 120 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 0.24 µL 1200 µL: ± 0.3%; ± 3.6 µL |
50 µL: ± 1.2%; ± 0.6 µL 120 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 0.24 µL 1200 µL: ± 0.3%; ± 3.6 µL |
50 µL: ± 1.2%; ± 0.6 µL 120 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 0.24 µL 1200 µL: ± 0.3%; ± 3.6 µL |
120 µL: ± 1.3%; ± 1.6 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 0.3%; ± 3.6 µL |
120 µL: ± 1.3%; ± 1.6 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 0.3%; ± 3.6 µL |
120 µL: ± 1.3%; ± 1.6 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 0.3%; ± 3.6 µL |
Systematic measurement error |
1 µL: ± 12%; ± 0.12 µL 2 µL: ± 8%; ± 0.16 µL 10 µL: ± 4%; ± 0.4 µL 20 µL: ± 2%; ± 0.4 µL |
1 µL: ± 15%; ± 0.15 µL 2 µL: ± 10%; ± 0.2 µL 10 µL: ± 4%; ± 0.4 µL 20 µL: ± 2%; ± 0.4 µL |
1 µL: ± 12%; ± 0.12 µL 2 µL: ± 8%; ± 0.16 µL 10 µL: ± 4%; ± 0.4 µL 20 µL: ± 2%; ± 0.4 µL |
1 µL: ± 15%; ± 0.15 µL 2 µL: ± 10%; ± 0.2 µL 10 µL: ± 4%; ± 0.4 µL 20 µL: ± 2%; ± 0.4 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 3%; ± 0.9 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 3%; ± 0.9 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 3%; ± 0.9 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
30 µL: ± 3.7%; ± 1.1 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.7%; ± 2.1 µL |
30 µL: ± 3.7%; ± 1.1 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.7%; ± 2.1 µL |
30 µL: ± 3.7%; ± 1.1 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.7%; ± 2.1 µL |
50 µL: ± 8%; ± 4 µL 120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
50 µL: ± 8%; ± 5 µL 120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
50 µL: ± 8%; ± 6 µL 120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
Autoclavable | yes (lower part) | yes | yes (lower part) | yes | yes (lower part) | yes | yes | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes | yes | yes | yes (lower part) | yes (lower part) | yes (lower part) | yes | yes | yes |
Power supply | 100 – 240 V ±10 %, 50 – 60 Hz | − | 100 – 240 V ±10 %, 50 – 60 Hz | − | 100 – 240 V ±10 %, 50 – 60 Hz | − | − | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | − | − | − | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | − | − | − |
Battery type | Rechargeable lithium polymer | − | Rechargeable lithium polymer | − | Rechargeable lithium polymer | − | − | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | − | − | − | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | − | − | − |
Consumables | only epT.I.P.S.® 384 | only epT.I.P.S.® 384 | only epT.I.P.S.® 384 | only epT.I.P.S.® 384 | only epT.I.P.S.® 384 | only epT.I.P.S.® 384 | only epT.I.P.S.® 384 | only epT.I.P.S.® 384 | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® |
Open system (third party consumables) | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes |
Delivery content | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5), O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5), O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5), O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Unlocking tool, O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Unlocking tool, O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Unlocking tool, O-ring tool | Pipette, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5), Unlocking tool, O-ring tool | Pipette, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5), Unlocking tool, O-ring tool | Pipette, Operating manual, Certificate, Adjustment tool, Adjustment seal for temporary adjustment (x5), Unlocking tool, O-ring tool |
- All Move It variants:
• ELISA
• Cell culture
• Cell-based assays
• (Real time) PCR
• Mouse genotyping
• Blood analysis
• FACS analysis
• Media transfer
• Dilution series
• Screening
Eppendorf Research plus Move It mechanical pipettes:
• Forward pipetting
• Reverse pipetting
• Removal of supernatants
• Sample mixing
• Phase extraction
• Filling of plates, gels, and reaction vessels
Eppendorf Xplorer plus Move It electronic pipettes:
• Automated pipetting of liquids (Pip) for forward pipetting
• Manual pipetting (Man) for volume determination
• Pipetting and mixing (P/M) for automated mixing of samples
• Dispensing (Dis) for manual filling of plates, gels, and reaction vessels
• Automatic dispensing (Ads) for automated filling of plates, gels, and reaction vessels
• Multi aspiration (Spc): Pooling supernatants from different vessels
• Sequential dispensing and pipetting (Spc) for user-defined volume steps
• Reverse pipetting (Spc) for non-aqueous solutions
• Diluting (Spc) for preparation of dilution series
• Fix volume (Fix): Save up to 10 volumes for ease of operation
- 4-, 6-, 8- and 12-channel air-cushion pipettes with variable volume and adjustable tip spacing option
- Available as mechanical (Research plus) and electronic (Xplorer plus) adjustable tip spacing multi-channel pipette
- For plates (384-, 96-, 48-, 24- and 12-well), tubes, agarose gels and more (depending on pipette variant)
- Tip spacing freely selectable from 4.5 to 33 mm, depending on pipette variant
- Format limiter for quick switches backwards and forwards between source and destination formats
- Manual adjustment knob for smooth vibration-free format switches and liquid transfers without dripping
- Tubeless system for enhanced reliability and safety
- Autoclavable for user and sample safety (Research plus fully, and Xplorer plus lower part only)
- 360° rotatable pipette head for comfortable readability of display and fast identification of parameters
- Optimally balanced pipette - reduces hand fatigue for stress-free operation