Mastercycler® X40 - PCR Thermocycler
Product Information
Mastercycler X40 combines properties that raise your standard in end-point PCR. Classic features such as a 12-column gradient and excellent block temperature homogeneity are enhanced by an easy, intuitive user interface, a touchscreen and a protective SafeLid to protect your samples from evaporation.You will find additional download material at the bottom of this page
Products (1)
Services (9)
Accessories (3)
1 Products
|
Show more Products
Added to Your Cart
Product Information
Technical Data
Applications
Features
Product Information
The Eppendorf Mastercycler X40 leads your standard PCR into a new era. Its futuristic design is paired with known quality. The performance of the reliable aluminum block is developed for excellent temperature homogeneity. A 12-column gradient offers fast PCR optimization. Programs from older Mastercycler models can easily be imported. Use the program migration feature to transfer protocols from other cycler models so that you can start right away. All programming is done fast, intuitive, and comfortably via a chemical-resistant glass surface touchscreen and the well-established user interface also used for Mastercycler X50. The handle can be operated with one hand and the SafeLid automatically adapts to apply the perfect pressure on your samples for evaporation protection. No matter if you use 0.1 mL, 0.2 mL tubes and tube strips, or PCR plates. Any type of PCR plate − skirted, semi-skirted and unskirted plates − can be used.
For monitoring and audit trails, you can connect the Mastercycler X40 directly to Visonize LabSuite and by connecting multiple Eppendorf Visionize onboard devices you can transform your lab into a digital lab.
All in a thermal cycler that is only slightly larger than a piece of paper and weighs just 7.25 kg.
Sustainability is a must, therefore the Mastercycler X40 is shipped in a stable, protective cardboard box. The short manual included is enough to start your PCR immediately and the full manual is available as a digital version, accessible via a QR code on the device.
For monitoring and audit trails, you can connect the Mastercycler X40 directly to Visonize LabSuite and by connecting multiple Eppendorf Visionize onboard devices you can transform your lab into a digital lab.
All in a thermal cycler that is only slightly larger than a piece of paper and weighs just 7.25 kg.
Sustainability is a must, therefore the Mastercycler X40 is shipped in a stable, protective cardboard box. The short manual included is enough to start your PCR immediately and the full manual is available as a digital version, accessible via a QR code on the device.
Improving ergonomics across the lab
Ergonomics goes far beyond just the »ergonomically designed chair«. At Eppendorf, we began optimizing our laboratory devices for ergonomics in the early 1970s.
In 2003, we launched the PhysioCare Concept®, focusing on ergonomic liquid handling devices, like our pipettes.
Nowadays, the Eppendorf PhysioCare Concept has broadened to include many laboratory products, including PCR cyclers. Our aim is to offer a holistic solution for harmonizing the workflow in your laboratory with your health and well-being.
For the Eppendorf Mastercyler range, this means:
› Ergonomically designed lid closure
› Low noise level for convenient working conditions at the bench
› Small footprint to enable position in direct arm reach at your bench
› Standardized »user-interface concept« for intuitive handling of devices
› Guided software for easy handling
Further information about the Eppendorf PhysioCare Concept:
www.eppendorf.com/physiocare/
Simple, intuitive documentation and tracking
The eLabJournal® Electronic Lab Notebook offers an intuitive and flexible solution to document research and track research data, including optimal PCR cycler temperatures and results. Improve efficiency when documenting, organizing, searching, and archiving collected data. With the free eLabJournal add-ons, you can extend the functionality of eLabJournal to a fully integrated Laboratory Information Management System.
Start a free 30-day trial!
Visit www.eLabJournal.com
Efficient lab and device management with VisioNize® Lab Suite
Are you interested in monitoring your lab devices and receiving notifications e.g., for device alarms? A digital, connected lab offers even more.
Gain access to a modular range of digital services and choose what works for your lab. VisioNize Lab Suite offers everything you need as a Lab Manager or Scientist to get started to digitally manage your lab for increased sample security, compliance needs and maintenance management.
Chart your own course to digital lab excellence! Find out more
Disposal of packaging
The packaging of the PCR cycler contains different materials, this includes cardboard, a plastic dust cover, and some foam parts. Recycling of materials becomes more and more important every day: Are you aware that nearly all cardboard material is recycled in Europe? Our cycler packaging cardboard material consists of approx. 60 % recycling material. Please support the global sustainability initiative of recycling valuable raw material by also collecting the cycler cardboard packaging material and disposing of it in the appropriate collection container at your organization. In respect to the plastic dust cover made of LD-PE and the foam parts, we recommend to select a dedicated recycling partner where PE material can be recycled. We suggest you contact your local waste hauler or facility management team to understand the available recycling options for your organization.
Disposal of instrument
Our cyclers last for many years, but if they need to be replaced, we kindly ask you to fulfill local requirements for disposal of these instruments. We strongly recommend a certified local recycling partner with experience in instruments with electronics. Keeping it "local" reduces the impact of transportation, and the "certified" aspect is recommended due to the safe and sustainable removal of specific parts.
Decontamination
This piece of equipment was used in a laboratory and/or was used to handle biological samples. Please keep in mind to adequately decontaminate the equipment which needs to be disposed. Check local requirements. For more information, get in contact with your local biosafety officer and/or waste officer. Check if your local recycling partner has special instructions and/or documentation requirements. You may also use the Eppendorf decontamination form sheet as guidance.
Read More
Read Less
Technical Data
Specifications | Mastercycler® X40 |
---|
ACT label | yes |
Thermoblock | Aluminum |
Sample capacity | 96-well plate or 0.1/0.2 mL tubes |
Heating technology | Three peltier elements |
Temperature control mode | Fast, Intermediate, Standard, Safe |
Temperature control range of the block | 4 – 99 °C |
Gradient range | 1 – 30 °C |
Gradient temperature control range | 30 – 99 °C |
Product type | PCR |
Heating rate | 3.3 °C/s |
Cooling rate | 1.5 °C/s |
Gradient block | over 12 columns |
Lid descent | SafeLid with thermal sample protection |
Lid temperature range | 37 – 110 °C |
Interfaces | Ethernet, USB |
Power supply | 100 – 240 V, 50 – 60 Hz |
Max. power consumption | 500 W |
Total weight | 7.25 kg |
Dimensions (W × D × H) | 24,5 × 38,5 × 23 cm / 9,7 × 15,2 × 9,1 in |
Remote Device Monitoring and Notifications (VisioNize®) | VisioNize® touch enabled |
Touchscreen Interface | yes |
Applications
- End-point PCR
- Cycle sequencing
- PCR optimization
- Incubation
Features
- Fast PCR optimization: Testing of 12 different denaturation/annealing temperatures in a single run with temperature gradient function
- Compatible with many vessel formats: 0.1/0.2 mL tubes and tube strips, 96 well plates (low/high profile unskirted, high profile semi-skirted, low profile skirted); SafeLid adjusts to different vessel heights for optimized temperature transfer and evaporation protection
- For more reproducible results: high block temperature homogeneity ±0.2 °C (20 – 72 °C) and control accuracy (±0.15 °C); constant 20 °C during warm-up phase of the heated lid reduces thermal load on samples and minimizes formation of non-specific products
- Supports sustainability goals: ACT-certified, low noise level and energy consumption: 40.5 db(A) and 0.134 kWh (3-step PCR run); energy-saving mode
- True control and remote monitoring: 7" touch interface e.g., with user management to set permissions to change settings or programs and detailed GLP- and audit supporting run documentation; remote monitoring and more with VisioNize® Lab Suite
- Easy program transfer: Program migration feature supports import of programs from slower cyclers, ramp rates are automatically adjusted according to the entered desired runtime
- Options and accessories: Dedicated service and maintenance plans e.g., IQ/OQ GxP or temperature verification with sensors calibrated according to ISO 9001 or ISO/IEC 17025, TVS-T6 block temperature verification system, broad selection of PCR consumables