BioBLU® f HNQ Single-Use Bioreactors
Información del producto
BioBLU f HNQ Single-Use Bioreactors are rigid- walled stirred-tank bioreactors suitable for use in clincal and commercial manufacturing. They are specifically designed for robust microbial applications using bacteria, yeasts, and fungi. The scalable BioBLU f HNQ portfolio covers working volumes up to 3.75 L. The rigid wall stirred tank design mimics traditional bioreactors and supports effective mixing and mass transfer making them suitable for high-cell density fermentation.Encontrará material adicional para descargar en laparte inferior de esta página
Productos (1)
1 Productos
N.o de catálogo
1386115000
|
Mostrar más productos
Añadido a su carro de la compra
Información del producto
Aplicaciones
Características
Información del producto
The BioBLU f HNQ Single-Use Bioreactors for microbial applications at a glance:
The rigid wall stirred tank design mimics traditional bioreactors and supports effective mixing and mass transfer making them suitable for high-cell density fermentation.
• BioBLU 1f HNQ (working volume 320 mL – 1.25 L)
• BioBLU 3f HNQ (working volume 1.25 L – 3.75 L)
Suitable for use in clinical and commercial manufacturing
• BioBLU HNQ Single-Use Bioreactors are available with LOT-specific Validation Guide, irradiation certificate, and the sterile- and endotoxin test report.
• We offer a unified solution package of bioprocess controllers, bioreactors, bioprocess SCADA software, and services that together support compliance of bioprocesses with GMP requirements.
Warning! Not approved for applications in medical diagnostics or therapy! The single-use vessel has not been developed for applications in medical diagnostics or therapy. It is not medical equipment within the meaning of Regulation (EU) 2017/745. Do not use the single-use vessel for medical or therapeutic applications.
The rigid wall stirred tank design mimics traditional bioreactors and supports effective mixing and mass transfer making them suitable for high-cell density fermentation.
• BioBLU 1f HNQ (working volume 320 mL – 1.25 L)
• BioBLU 3f HNQ (working volume 1.25 L – 3.75 L)
Suitable for use in clinical and commercial manufacturing
• BioBLU HNQ Single-Use Bioreactors are available with LOT-specific Validation Guide, irradiation certificate, and the sterile- and endotoxin test report.
• We offer a unified solution package of bioprocess controllers, bioreactors, bioprocess SCADA software, and services that together support compliance of bioprocesses with GMP requirements.
Warning! Not approved for applications in medical diagnostics or therapy! The single-use vessel has not been developed for applications in medical diagnostics or therapy. It is not medical equipment within the meaning of Regulation (EU) 2017/745. Do not use the single-use vessel for medical or therapeutic applications.


Bioreactor body and head plate
• Stirred-tank design: The stirred-tank design offers reliability scalability and facilitates the easy replacement of traditional glass bioreactors.
• Equipment: BioBLU Single-Use Bioreactors are assembled with sparger, overlay, gas filters for inlet and exhaust as well as penetrations for pH, DO, and temperature sensors, liquid additions, sampling, and harvest. All head plate ports are clearly marked for ease of use. Spare Pg 13.5 ports can be equipped with single-use septa, tri-ports and compression fitting adaptors for more flexibility.
• Sterilization: BioBLU 1f HNQ Single-Use Bioreactors are delivered sterile. Irradiated by > 25 kGy (X-ray). SAL-level 10-6 for X-ray irradiated BioBLU Single-Use Bioreactors. The BioBLU 3f HNQ Single-Use Bioreactor is not presterilized and is autoclavable.




Suitable for high cell densities
BioBLU f HNQ Single-Use Bioreactors support the high mass transfer and heat removal requirements of fermentation processes.
• Motor: Powerful overhead drives enable high agitation speeds. Sealed magnetic drive with fully enclosed bearings maintain vessel sterility.
• Baffles: Interior baffles aid mixing and mass transfer. The baffles of the BioBLU 1f HNQ additionally provide efficient heat removal through active cooling.
• Impellers: Multiple Rushton-type impellers for efficient mixing and mass transfer.
• Cooling: Smart solutions for cooling using cooling baffles or cooling fingers.
• Exhaust treatment: Effective liquid-free exhaust condensation (Peltier), electric heater band or water-cooled exhaust treatment.


Leer más
Leer menos
Aplicaciones
- Cultivation of bacteria, yeasts, and fungi.
- Suitable for high-cell density fermentation.
- For the cultivation of human and animal cells we offer the BioBLUc HNQ Single-Use Bioreactor product line.
Características
- Single-use, stirred-tank, rigid-walled bioreactors available in sizes ranging of up to 3.75 L working volume
- Designed for high-density fermentation processes
- Multiple Rushton-type impellers for efficient mixing and mass transfer
- Sealed magnetic drive with fully enclosed bearings maintain vessel sterility
- Baffles for excellent mixing and mass transfer
- Bioreactors are assembled with sparger, gas filters for inlet and exhaust as well as penetrations for pH, DO, temperature, liquid additions, sampling, and harvest
- For use with Eppendorf bioreactor systems